FLK Gas Sampling System - MPIP - Free
FLK Gas Sampling System - MPIP - Free
FLK Gas Sampling System - MPIP - Free
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SQ256 Retraction Device<br />
1. Introduction<br />
1.1 General information<br />
Warning!<br />
This system is operated by electricity. When operating electrical equipment, it is unavoidable<br />
that certain parts of this system carry a dangerous voltage.<br />
If the warning information is not followed, serious bodily injury and/or material damage may<br />
occur.<br />
Only appropriately qualified personnel should work on this equipment or in its vicinity. These<br />
persons must be thoroughly acquainted with all the warnings and maintenance precautions in<br />
accordance with this manual.<br />
The proper and safe operation of this device requires correct transport, storage, mounting<br />
and mounting as well as proper operation and maintenance.<br />
In particular the general construction and safety regulations about working on power<br />
installations (e.g. DIN, VDE) should be followed as well as the regulations relating to the<br />
proper use of lifting equipment and tools and the use of personal protective gear (protective<br />
goggles, etc.).<br />
1.2 Personnel qualification requirements<br />
As understood in this operating manual and on warning notices qualified personnel are persons who are<br />
acquainted with the mounting, mounting, maintenance and operation of this product and who possess appropriate<br />
qualifications for their occupation, such as for example covering:<br />
- training or instruction, and authorization for installing, removing, earthing and labelling power circuits,<br />
equipment and systems according to the currently valid standards of safety engineering,<br />
- training or instruction according to the currently valid standards of safety engineering in the care and use of<br />
adequate safety equipment;<br />
- training in first aid.<br />
This product left our factory in a perfectly safe condition. In order to maintain this condition and ensure the safe<br />
operation of the device, the information and warning notes given in this manual must be observed.<br />
1.3 Field of application<br />
For the application of the motor-driven retraction device for inserting and withdrawing the gas-sampling probe, the<br />
following points are decisive with respect to the manual mounting and to the retraction device itself:<br />
- Application conditions of the probe in the hot kiln region<br />
- Weight of approx. 130 kg<br />
- When a fault occurs, the gas-sampling probe can be retracting quickly from the kiln to protect it from damage.<br />
- Baked-on materials on the cooling pipe of the probe are stripped off by "Retraction / Insertion" of the probe.<br />
- Automation of the insertion and retraction increases the convenience and safety in operation.<br />
- The maintenance effort is reduced.<br />
- It enables a centralized assembly of the sampling pipe, valve combination and dust removal filter.<br />
Copyright ® SIEMENS Page 95 04/04