SQ256 Retraction Device<br />

1. Introduction<br />

1.1 General information<br />

Warning!<br />

This system is operated by electricity. When operating electrical equipment, it is unavoidable<br />

that certain parts of this system carry a dangerous voltage.<br />

If the warning information is not followed, serious bodily injury and/or material damage may<br />

occur.<br />

Only appropriately qualified personnel should work on this equipment or in its vicinity. These<br />

persons must be thoroughly acquainted with all the warnings and maintenance precautions in<br />

accordance with this manual.<br />

The proper and safe operation of this device requires correct transport, storage, mounting<br />

and mounting as well as proper operation and maintenance.<br />

In particular the general construction and safety regulations about working on power<br />

installations (e.g. DIN, VDE) should be followed as well as the regulations relating to the<br />

proper use of lifting equipment and tools and the use of personal protective gear (protective<br />

goggles, etc.).<br />

1.2 Personnel qualification requirements<br />

As understood in this operating manual and on warning notices qualified personnel are persons who are<br />

acquainted with the mounting, mounting, maintenance and operation of this product and who possess appropriate<br />

qualifications for their occupation, such as for example covering:<br />

- training or instruction, and authorization for installing, removing, earthing and labelling power circuits,<br />

equipment and systems according to the currently valid standards of safety engineering,<br />

- training or instruction according to the currently valid standards of safety engineering in the care and use of<br />

adequate safety equipment;<br />

- training in first aid.<br />

This product left our factory in a perfectly safe condition. In order to maintain this condition and ensure the safe<br />

operation of the device, the information and warning notes given in this manual must be observed.<br />

1.3 Field of application<br />

For the application of the motor-driven retraction device for inserting and withdrawing the gas-sampling probe, the<br />

following points are decisive with respect to the manual mounting and to the retraction device itself:<br />

- Application conditions of the probe in the hot kiln region<br />

- Weight of approx. 130 kg<br />

- When a fault occurs, the gas-sampling probe can be retracting quickly from the kiln to protect it from damage.<br />

- Baked-on materials on the cooling pipe of the probe are stripped off by "Retraction / Insertion" of the probe.<br />

- Automation of the insertion and retraction increases the convenience and safety in operation.<br />

- The maintenance effort is reduced.<br />

- It enables a centralized assembly of the sampling pipe, valve combination and dust removal filter.<br />