SQ254 Heat Exchanger<br />

1.5 Technical data<br />

Operating Voltage Volt 380-480<br />

Frequency Hz 50/60<br />

Control Voltage Volt 24 V DC from control unit<br />

Frequency Hz 50/60<br />

Cooling capacity kW 65<br />

Circulation pump<br />

Power of motor kW 2.2<br />

Motor speed 1/min 3460<br />

Fan<br />

Power of motor kW 0,52<br />

Motor speed 1/min 1340<br />

Heat exchanger<br />

Inlet temperature of air °C max. 45<br />

Outlet temperature of air °C appr. 105<br />

Inlet temperature of medium °C 200<br />

Outlet temperature of medium °C 170<br />

Cooling surface m 2 25<br />

Cooling unit<br />

Weight, incl. filling kg appr. 420<br />

Protection type IP 54<br />

Cooling medium<br />

synthetic heat transfer liquid<br />

Total content of the unit ltr. appr. 50<br />

The performance data mentioned above are guaranteed provided that Siemens approved heat transfer liquid is<br />

used as a cooling medium. Do not use other cooling medium than specified by Siemens.<br />

For service, power supply and serial number please refer to the nameplate on the switch cabinet.<br />

Factory Settings<br />

Temperature of thermostat to be adjusted for 3 way valve 140 °C<br />

Switch temperature for start fan to be adjusted at the Temp.-controller 180 °C<br />

Maximum temperature to be adjusted at the Temp.-controller 220 °C<br />

Minimum temperature to be adjusted at the Temp.-controller 130 °C<br />

Minimum flow to be adjusted at the flow meter 1.5m 3 /h<br />

Minimum level in compensating tank over bottom<br />

85 mm<br />

Copyright ® SIEMENS Page 79 04/04