SQ251 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe<br />
2 Installation<br />
2.1 <strong>Gas</strong> sampling probe<br />
The gas-sampling probe can basically be installed according to requirements, but the following possible methods<br />
should be considered.<br />
• On a manual retraction device.<br />
• On an automatic retraction device.<br />
It should be ensured however that the probe is mounted at an angle of about 5° sloping down to the probe tip.<br />
This prevents the formation of air bubbles in the probe.<br />
A fixed installation of the probe is not recommended.<br />
• Because if the cooling fails (also with power failure) and with cessation of the flow, dangerous coolant<br />
overheating may occur.<br />
• The weight of the probe is about 130 kg.<br />
• Excessive material deposits on the cooling pipe lead to increased mechanical loading and to excessive<br />
cooling of the cooling medium. When the cooling medium cools below the acid dew point, this leads to<br />
blockage of the sampling pipe. The probe would then have to be removed for cleaning.<br />
With an installation with a manual retraction device, appropriate mounting holes for the probe must be provided on<br />
the carriage together with mounting for the valve combination and the dust removal filter.<br />
Note:<br />
Installation plans must be requested from the relevant SIEMENS subsidiary.<br />
Mountings are provided for the probe, valve combination and dust removal filter for installation with an automatic<br />
retraction device.<br />
After mounting the retraction device, the probe is placed on the carriage and fastened to it (see Figure 3).<br />
See the separate operating manual for the installation of the retraction device.<br />
Copyright ® SIEMENS Page 36 04/04