SQ253 Valve Combination<br />
4.5 Four-way ball valve<br />
The 4-way ball valve is constructed in steel with an electrical actuator drive to DIN ISO 5211/3337.<br />
The ball valve material is complete in PEEK. The full sealing tightness is achieved by a pressure-aided, maintenance-free<br />
sealing system.<br />
The actuator drive is also maintenance-free and fitted with an anti-blocking motor with temperature monitoring.<br />
4.5.1 Removing the 4-way ball valve<br />
• Remove inside the housing of the 4 Way-valve. Loosen the 2 screws inside the valve box and remove the valve<br />
from the drive.<br />
Note: Attention must be paid to the connecting cable. This is so long that the complete unit can be lifted<br />
out.<br />
4.5.1.1 Checking the limit switches:<br />
• Remove the complete unit as described above.<br />
• Check the position of the 4 limit switches<br />
• The control is provided by the OP3 in the control cabinet.<br />
• A selected position is approached by entry in the CTR 16 (e.g. Measure).<br />
• Assembly takes place in the reverse sequence.<br />
Important! When setting the limit switches, pay attention to the 24VDC control voltage.<br />