1. Introduction<br />
1.1 General information<br />
Warning! This system is operated by electricity. When operating electrical equipment, it is unavoidable that<br />
certain parts of this system carry a dangerous voltage.<br />
If the warning information is not followed, serious bodily injury and/or material damage may<br />
occur.<br />
Only appropriately qualified personnel should work on this equipment or in its vicinity. These<br />
persons must be thoroughly acquainted with all the warnings and maintenance precautions in<br />
accordance with this manual.<br />
The proper and safe operation of this device requires correct transport, storage and<br />
well as proper operation and maintenance.<br />
mounting as<br />
In particular the general construction and safety regulations about working on power installations (e.g.<br />
DIN, VDE) should be followed as well as the regulations relating to the proper use of lifting<br />
equipment and tools and the use of personal protective gear (protective goggles, etc.).<br />
1.2 Personnel qualification requirements<br />
As understood in this operating manual and on warning notices qualified personnel are persons who are acquainted with the<br />
mounting, maintenance and operation of this product and who possess appropriate qualifications for their occupation, such as<br />
for example covering:<br />
- training or instruction, and authorization for installing, removing, earthing and labeling power circuits, equipment and<br />
systems according to the currently valid standards of safety engineering,<br />
- training or instruction according to the currently valid standards of safety engineering in the care and use of<br />
adequate safety equipment;<br />
- training in first aid.<br />
This product left our factory in a perfectly safe condition. In order to maintain this condition and ensure the safe operation of<br />
the device, the information and warning notes given in this manual must be observed.<br />
1.3 Field of application<br />
The control unit is used to control the complete <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe which are mainly used for measuring gas sampling<br />
up to approx. 1800 °C with a high dust content.<br />
Due to the high dust concentration in the process gas, dust deposits in the sampling probe and in the heated filter are<br />
unavoidable. Therefore, automatic, cyclical cleaning has been implemented for the probe and the filter. The mechanical parts<br />
required for this are accommodated in the valve combination. If a compressed air motor is being used for the "emergency<br />
withdrawal" of the probe, the control valves needed for the motor are also in the valve combination.<br />
Note:<br />
See also the general operating manual for the <strong>FLK</strong> Probe.<br />
Copyright ® SIEMENS Page 87 04/04