SQ250 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> <strong>System</strong><br />
Fig. 3 Coolant circuit for sampling probe<br />
Legends:<br />
1 <strong>Gas</strong> sampling probe<br />
2 <strong>Gas</strong> sampling opening<br />
3 Coolant connection<br />
4 Retraction device<br />
7 Heat exchanger<br />
8 Installation pipe<br />
60 Coolant circulation pump<br />
61 Level monitoring<br />
62 Cooler with fan<br />
63 Expansion vessel<br />
64 Thermal switch<br />
65 Three-way control valve<br />
66 Flow monitor<br />
67 Temperature sensor<br />
68 Shut-off valve<br />
69 Coolant filter<br />
70 Coolant line<br />
71 Dust blow-back<br />
72 Corrugated hose<br />
82 Dust-laden measuring gas<br />
83 Control cable to control cabinet<br />
85 Control cable for retraction device<br />
The concept of the unpressurised, enclosed coolant circuit was selected for the cooling of the special synthetic heat transfer<br />
fluid. The liquid-air cooler with an expansion vessel, which handles the cooling of the heat transfer fluid, is the centre-piece<br />
of the heat exchanger unit. The axial fan provides the required air flow and the maintenance-free, high-temperature resistant<br />
centrifugal pump circulates the heat transfer fluid.<br />