SQ253 Valve Combination<br />

4.4 Condensate separator<br />

The condensate separator consists of a glass bulb, lower and upper cover plates in stainless steel each with a connection<br />

opening and O-rings between the glass bulb and covers. Since the condensate vessel is blown out with each flushing process,<br />

no maintenance work is required.<br />

When replacing the various parts, it should be ensured during assembly that the four threaded bolts with hexagon nuts are<br />

tightened evenly and that the O-rings are correctly seated.<br />

If any leaks occur:<br />

• First, slightly, but evenly tighten the threaded bolts.<br />

• Check the glass bulb for any damage.<br />

• Check the O-rings.<br />