2 Installation<br />
2.1 General information<br />
Great importance is given to the point of installation of the retraction device, because the run of the probe and<br />
therefore its measuring point are then defined. There are mainly two different fields in the cement industry where<br />
the probe can be installed:<br />
• Kiln inlet<br />
• Precalcination<br />
It is essential that the installation location and the mounting are defined, with respect to the space requirement,<br />
between the machine supplier or user and SIEMENS<br />
2.2 Point of installation<br />
• Suitable installation space for the insertion and retraction of the probe and for the movement of the feed lines<br />
such as coolant hoses, compressed air, measuring gas and cables must be provided for the complete<br />
retraction device.<br />
• Similarly accessibility in the probe's inserted and retract state should be ensured for installation and<br />
maintenance work.<br />
• The traverse rail should be sloped approx. 1 ... 5° forward to prevent the formation of air pockets in the<br />
coolant in the probe.<br />
• If required, coverage should be provided against rain or falling material (e.g. poker holes).<br />
• On the platform a base-plate should be provided under the retraction device to prevent risk to persons from<br />
falling deposits on the probe.<br />
• It should be ensured that there are no cables or heat-sensitive parts under the retract probe.<br />
2.2.1 Fitting on the kiln inlet<br />
The following points should be followed for gas analysis on the kiln inlet:<br />
Preferentially the probe should be fitted at the side on the kiln inlet chamber.<br />
It should be positioned slightly oblique to the kiln axis.<br />
The probe should be fitted to the side opposite to the side on which the material is fed.<br />
In the inserted state the probe must protrude at least 30 cm behind the rotary seal in the kiln (vertical distance).<br />
The probe must not pass through the material flow from the heat exchanger.<br />
It should be ensured that no baked-on deposits can fall down from the heat exchanger onto the probe.<br />
The probe must have a distance of at least 20 cm from the lining of the rotary kiln. When installing the probe in a<br />
new kiln, pay attention to the lining and kiln expansion in the hot state.<br />
2.2.2 Installation in the heat exchanger ( precalcination chamber)<br />
The following points should be followed for gas analysis in the heat exchanger:<br />
The probe must be installed in an area as free of dust as possible. This position is normally after a cyclone and<br />
under a diffusion box.<br />
In the inserted state this probe must protrude at least 1/3, but at the most up to the middle of the gas line.<br />
The installation location should also be so planned such that the effects of heat on retraction device are not too<br />
high.<br />
With this installation location a closing flap should be fitted if possible to the installation pipe by the customer<br />
(either automatic or manual).<br />