SQ256 Retraction Device<br />

2 Installation<br />

2.1 General information<br />

Great importance is given to the point of installation of the retraction device, because the run of the probe and<br />

therefore its measuring point are then defined. There are mainly two different fields in the cement industry where<br />

the probe can be installed:<br />

• Kiln inlet<br />

• Precalcination<br />

It is essential that the installation location and the mounting are defined, with respect to the space requirement,<br />

between the machine supplier or user and SIEMENS<br />

2.2 Point of installation<br />

• Suitable installation space for the insertion and retraction of the probe and for the movement of the feed lines<br />

such as coolant hoses, compressed air, measuring gas and cables must be provided for the complete<br />

retraction device.<br />

• Similarly accessibility in the probe's inserted and retract state should be ensured for installation and<br />

maintenance work.<br />

• The traverse rail should be sloped approx. 1 ... 5° forward to prevent the formation of air pockets in the<br />

coolant in the probe.<br />

• If required, coverage should be provided against rain or falling material (e.g. poker holes).<br />

• On the platform a base-plate should be provided under the retraction device to prevent risk to persons from<br />

falling deposits on the probe.<br />

• It should be ensured that there are no cables or heat-sensitive parts under the retract probe.<br />

2.2.1 Fitting on the kiln inlet<br />

The following points should be followed for gas analysis on the kiln inlet:<br />

Preferentially the probe should be fitted at the side on the kiln inlet chamber.<br />

It should be positioned slightly oblique to the kiln axis.<br />

The probe should be fitted to the side opposite to the side on which the material is fed.<br />

In the inserted state the probe must protrude at least 30 cm behind the rotary seal in the kiln (vertical distance).<br />

The probe must not pass through the material flow from the heat exchanger.<br />

It should be ensured that no baked-on deposits can fall down from the heat exchanger onto the probe.<br />

The probe must have a distance of at least 20 cm from the lining of the rotary kiln. When installing the probe in a<br />

new kiln, pay attention to the lining and kiln expansion in the hot state.<br />

2.2.2 Installation in the heat exchanger ( precalcination chamber)<br />

The following points should be followed for gas analysis in the heat exchanger:<br />

The probe must be installed in an area as free of dust as possible. This position is normally after a cyclone and<br />

under a diffusion box.<br />

In the inserted state this probe must protrude at least 1/3, but at the most up to the middle of the gas line.<br />

The installation location should also be so planned such that the effects of heat on retraction device are not too<br />

high.<br />

With this installation location a closing flap should be fitted if possible to the installation pipe by the customer<br />

(either automatic or manual).<br />

Copyright ® SIEMENS Page 98 04/04