obd2cartool.com Tech-2-User-Guide
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SECTION VIIB<br />
TIS SOFTWARE<br />
Viewing Capture Info Data<br />
Capture Info is a feature that allows the <strong>Tech</strong> 2 to retrieve DTCs, Freeze Frame and Failure Records from<br />
the vehicle’s control module. This is a different function than snapshot display. Capture Info files consist of<br />
only one frame of data, whereas snapshots typically contain multiple frames of data.<br />
When Capture Info is selected (refer to p. VII-4), the scan tool displays a menu selection that allows data<br />
from the control module to be stored to the <strong>Tech</strong> 2 PCMCIA card, or to refresh the PCMCIA card with new<br />
data from a control module.<br />
IMPORTANT<br />
A single code may be counted as two different codes in a Capture Info file if it exists both in freeze<br />
frame and failure records (Figure VIIB-28).<br />
To view DTCs, freeze frame or failure record data through TIS software:<br />
1. Use the <strong>Tech</strong> 2 Capture Info function to retrieve data from a vehicle’s control module.<br />
2. Connect the <strong>Tech</strong> 2 to the <strong>com</strong>puter (Figure VIIB-4) and go to the <strong>Tech</strong> 2 start-up screen (Figure VI-1).<br />
3. Launch TIS.<br />
4. Select the Snapshot Upload/Display application.<br />
Figure VIIB-28<br />
Viewing Capture Info data on the Snapshot Upload/Display screen<br />
Viewing Capture Info Data continued on next page...<br />
2005 <strong>Tech</strong> 2 <strong>User</strong>’s <strong>Guide</strong> VII - 32