46<br />

SG<br />

Z<br />

Z1 = 800 + y<br />

Z2 = 800 + x<br />

Montage<br />

Weiche<br />

Elektrische Installation<br />

Die elektrische Ausrüstung wird in<br />

3 Versionen geliefert:<br />

Steuerungsart 1<br />

(Standardausführung)<br />

Die kompl<strong>et</strong>te Steuerung 20.50 ist<br />

anschlußfertig am Weichenrahmen<br />

angebaut.<br />

Die Zuleitung "Z" und das eventuell<br />

lose mitgelieferte Steuergerät<br />

"SG" ist nach <strong>de</strong>n Schaltplänen<br />

anschließen, ↑ 146.<br />

Bei <strong>de</strong>r Installation darauf achten,<br />

daß das Steuergerät "SG"<br />

nicht im Fahrbereich <strong>de</strong>r Fahrwerke<br />

bzw. <strong>de</strong>r Last hängt.<br />

Frei herabhängen<strong>de</strong>s Steuergerät<br />

immer mit Zugentlastungsseil<br />

aufhängen, ↑ Skizze.<br />

Steuerungsart 2<br />

Die Steuerungsart 2 enthält eine<br />

seperate Überwachungseinrichtung<br />

20.55, die in Verbindung<br />

mit <strong>de</strong>r Steuerungsart 1 am<br />

Weichenrahmen 20.01 angebaut<br />

ist, ↑ 48.<br />

Die Überwachung verhin<strong>de</strong>rt ein<br />

Verstellen <strong>de</strong>r Weiche, wenn<br />

Fahrwerke im Weichenbereich<br />

sind, o<strong>de</strong>r ein Einfahren <strong>de</strong>s<br />

Fahrwerks in <strong>de</strong>n Weichenbereich,<br />

solange die Weiche nicht<br />

in einer Endstellung steht.<br />

An <strong>de</strong>n drei Weichenanschlüssen<br />

müssen Trennstellen in <strong>de</strong>n<br />

Leitern eingebaut sein, ↑ Skizze.<br />

Die Lage ist von <strong>de</strong>n Fahrwerkslängen<br />

abhängig. Die Einspeisungen<br />

für diese Schleifleitungsstücke<br />

sind an <strong>de</strong>n<br />

Weichenanschlußbahnträgern<br />

eingebaut.<br />

Bei Direktsteuerung <strong>de</strong>r Fahrwerke<br />

muß zusätzlich ein Schütz am<br />

Hebezeug eingebaut wer<strong>de</strong>n.<br />

Bei Schützsteuerung muß <strong>de</strong>r<br />

Steuertrafo immer an L2 und L3<br />

angeschlossen wer<strong>de</strong>n.<br />

Siehe Schaltplanunterlagen, ↑146.<br />

*1 Stromeinspeisung<br />

*2 Trennstelle L1 und L2<br />

Assembly<br />

Track switch<br />

Electrical installation<br />

Three types of electrical<br />

equipment are available:<br />

Control type 1<br />

(standard version)<br />

The compl<strong>et</strong>e control equipment<br />

20.50 is mounted on the switch<br />

frame ready for connection.<br />

Power supply cable "Z" and<br />

thecontrol pendant "SG" if<br />

supplied loose, should be<br />

connected according to the<br />

circuit diagrams, ↑ 146.<br />

When installing, take care that<br />

the control pendant "SG" is not<br />

suspen<strong>de</strong>d in the area traversed<br />

by the travel units or the load.<br />

Always support a freely<br />

suspen<strong>de</strong>d control pendant with<br />

a strain relief wire, ↑ sk<strong>et</strong>ch.<br />

Control type 2<br />

Control type 2 inclu<strong>de</strong>s a separate<br />

monitoring arrangement 20.55<br />

which is mounted on the switch<br />

frame 20.01 in connection with<br />

control type 1, ↑ 48.<br />

This monitoring <strong>de</strong>vice prevents<br />

the track switch being operated if<br />

travel units are in the vicinity of<br />

the switch, or a travel unit moving<br />

into the vicinity of the switch,<br />

unless the switch is in an end<br />

position.<br />

Iisolating sections must be<br />

installed in the leads at the three<br />

switch connection points, ↑<br />

sk<strong>et</strong>ch.<br />

Their position <strong>de</strong>pends on the<br />

lengths of the travel units. The<br />

power feeds for these sections of<br />

bus bar are fitted to the connecting<br />

gir<strong>de</strong>rs for the switch.<br />

With direct control of the travel<br />

units, an additional contactor must<br />

be installed on the hoist.<br />

With contactor control, the control<br />

transformer must always be<br />

connected to L2 and L3.<br />

See circuit diagrams, ↑ 146.<br />

*1 Power feed<br />

*2 Disconnect point L1 and L2<br />

Montage<br />

Aiguillage<br />

Installation électrique<br />

L'équipement électrique est livré<br />

en trois versions :<br />

Type <strong>de</strong> comman<strong>de</strong> 1<br />

(version standard)<br />

La comman<strong>de</strong> 20.50 complète est<br />

montée sur le châssis <strong>de</strong> l'aiguillage,<br />

prête à être branchée.<br />

Brancher suivant les schémas<br />

électriques la ligne d'alimentation<br />

"Z" <strong>et</strong> le boîtier <strong>de</strong> comman<strong>de</strong><br />

"SG" éventuellement joint non<br />

raccordé à la fourniture, ↑ 146.<br />

Lors <strong>de</strong> l'installation, veiller à ce<br />

que le boîtier <strong>de</strong> comman<strong>de</strong> "SG"<br />

ne soit pas suspendu dans la<br />

zone <strong>de</strong> déplacement <strong>de</strong>s<br />

chariots ou <strong>de</strong> la charge.<br />

Toujours pourvoir d'un câble <strong>de</strong><br />

détente la boîte <strong>de</strong> comman<strong>de</strong><br />

suspendu librement, ↑ croquis.<br />

Type <strong>de</strong> comman<strong>de</strong> 2<br />

Le type <strong>de</strong> comman<strong>de</strong> 2 comprend un<br />

dispositif <strong>de</strong> surveillance séparé 20.55<br />

qui est monté sur le châssis <strong>de</strong><br />

l'aiguillage 20.01 en combinaison avec<br />

le type <strong>de</strong> comman<strong>de</strong> 1, ↑ 48.<br />

La surveillance empêche un déréglage<br />

<strong>de</strong> l'aiguillage quand les chariots<br />

sont dans la zone d'aiguillage, ou la<br />

pénétration du chariot dans la zone<br />

d'aiguillage tant que l'aiguillage n'est<br />

pas à une position extrême.<br />

Des points <strong>de</strong> sectionnement<br />

doivent être incorporés aux lignes<br />

<strong>de</strong>s trois raccor<strong>de</strong>ments<br />

d'aiguillage, ↑ croquis.<br />

La position est fonction <strong>de</strong> la<br />

longueur <strong>de</strong>s chariots. Les<br />

alimentations <strong>de</strong> ces tronçons <strong>de</strong><br />

lignes à contacts glissants sont<br />

intégrées aux coupons <strong>de</strong><br />

raccor<strong>de</strong>ments d'aiguillage.<br />

En cas <strong>de</strong> comman<strong>de</strong> directe <strong>de</strong>s<br />

chariots, il doit, <strong>de</strong> plus, être monté un<br />

contacteur sur l'appareil <strong>de</strong> levage.<br />

En cas <strong>de</strong> comman<strong>de</strong> par<br />

contacteurs, le transformateur <strong>de</strong><br />

comman<strong>de</strong> doit toujours être<br />

raccordé à L2 <strong>et</strong> L3.<br />

Voir schémas électriques, ↑ 146.<br />

*1 Alimentation électrique<br />

*2 Points <strong>de</strong> sectionnement L1 <strong>et</strong> L2<br />

06.02<br />

bakt05a