Denmark's National Inventory Report 2005 - Submitted under the ...
Denmark's National Inventory Report 2005 - Submitted under the ...
Denmark's National Inventory Report 2005 - Submitted under the ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
7. Bjerrum M., 2002. Danish Technological Institute, personal communication 09-10-2002<br />
8. Kristensen, P. (2004) Danish Gas Technology Centre, e-mail 31-03-2004<br />
9. NERI calculation based on annual environmental reports of Danish plants year 2000<br />
10. Risø <strong>National</strong> Laboratory home page - http://www.risoe.dk/sys/esy/emiss_e/emf25082000.xls<br />
11. Gruijthuijsen L.v. & Jensen J.K., 2000. Energi- og miljøoversigt, Danish Gas Technology Centre 2000 (In Danish)<br />
12. Dyrnum O., Warnøe K., Manscher O., Vikelsøe J., Grove A.., Hansen K.J., Nielsen P.A., Madsen H. 1990, Miljøprojekt 149/1990<br />
Emissions<strong>under</strong>søgelse for pejse og brændeovne, Miljøstyrelsen (In Danish)<br />
13. Hansen K.J., Vikelsøe J., Madsen H. 1994, Miljøprojekt 249/1994 Emissioner af dioxiner fra pejse og brændeovne, Miljøstyrelsen<br />
(In Danish)<br />
14. Danish Gas Technology Centre 2001, Naturgas – Energi og miljø (In Danish)<br />
15. Same emission factors as for gas oil is assumed (NERI assumption)<br />
16. Same emission factors as residual oil assumed (NERI assumption)<br />
17. NERI calculation based on S content of natural gas 6mg(S)/mn 3 gas. The S content refers to <strong>the</strong> Danish natural gas transmission<br />
company Gastra (http://www.gastra.dk/dk/index.asp)<br />
18. Estimated by NERI based on 2003 data reported by <strong>the</strong> plant owners to <strong>the</strong> electricity transmission companies and <strong>the</strong> Danish<br />
Energy Authority. NERI calculations are based on data forwarded by <strong>the</strong> Danish Energy Authority: Nielsen M. 2004. Energistyrelsen,<br />
personal communication, e-mail 28-06-2004.<br />
19. NERI calculation based on a sulphur content of 0,8% and a retention of sulphur in ash of 5%. The sulphur content has been<br />
assumed just below <strong>the</strong> limit value of 0,9% (reference no. 24)<br />
20. NERI calculation based on a sulphur content of 1% (reference no. 24) and a retention of sulphur in ash of 5%.<br />
21. Christiansen, B.H., Evald, A., Baadsgaard-Jensen, J. Bülow, K. 1997. Fyring med biomassebaserede restprodukter, Miljøprojekt<br />
nr. 358, 1997, Miljøstyrelsen<br />
22. Serup H., Falster H., Gamborg C., G<strong>under</strong>sen P., Hansen L. Heding N., Jacobsen H.H., Kofman P., Nikolaisen L., Thomsen I.M.<br />
1999. Træ til energiformål, Teknik – Miljø – Økonomi, 2. udgave, 1999, Videncenter for halm og flisfyring (In Danish)<br />
23. NERI calculation based on a sulphur content of 0,0003%. The approximate sulphur content is stated by Danish refineries.<br />
24. Miljøstyrelsen, 2001.Bekendtgørelseom begrænsning af svovlindholdet i visse flydende og faste brændstoffer, Bekendtgørelse<br />
532 af 25/05/2001 (Danish legislation)<br />
25. NERI calculation based on a sulphur content of 0,7%. The sulhpur content refer to product data from Shell and Statoil available at<br />
<strong>the</strong> internet at: http://www.statoil.dk/mar/svg01185.nsf/fs/erhverv-produkt (13-05-2004)<br />
26. NERI calculation based on a H2S content of 200 ppm. The H2S content refer to Christiansen J. 2003, Personal communicationÃand<br />
to Hjort-Gregersen K., 1999 Centralised Biogas Plants, Danish Institute of Agricultural and Fisheries Economics, 1999<br />
27. NERI calculation based on a sulphur content of 0,05% S. The sulphur content refers to Bilag 750, Kom 97/0105<br />
(http://www.folketinget.dk/?/samling/20041/MENU/00000002.htm) and to product sheets from Q8, Shell and Statoil<br />
28. Miljøstyrelsen 1990. Bekendtgørelse om begrænsning af emissioner af svovldioxid, kvælstofoxider og støv fra store fyringsanlæg,<br />
Bekendtgørelse 689 af 15/10/1990 (Danish legislation)<br />
29. Same emission factor as for coal is assumed (NERI assumption)<br />
30. Product sheet from Shell. Available on <strong>the</strong> internet at: http://www.shell.com/home/dkda/html/iwgen/app_profile/app_products_0310_1510.html<br />
(13-05-2004)<br />
31. Nielsen, M. & Illerup, J.B: 2003. Emissionsfaktorer og emissionsopgørelse for decentral kraftvarme. Eltra PSO projekt 3141.<br />
Kortlægning af emissioner fra decentrale kraftvarmeværker. Delrapport 6. Danmarks Miljø<strong>under</strong>søgelser. 116 s. –Faglig rapport<br />
fra DMU nr. 442.(In Danish, whith an english summary). Available on <strong>the</strong> Internet at :<br />
http://www2.dmu.dk/1_viden/2_Publikationer/3_fagrapporter/rapporter/FR442.pdf<br />
32. Revised 1996 IPCC Guidelines for <strong>National</strong> Greenhouse Gas Inventories: Reference Manual, 1996. Available on <strong>the</strong> Internet at<br />
http://www.ipcc-nggip.iges.or.jp/public/gl/invs6.htm (11-04-<strong>2005</strong>)<br />
33. NERI calculation based on plant specific data 2003<br />
34. NERI calculation based on plant specific data 2002<br />
35. Same emission factor as for natural gas fuelled gas turbines is assumed<br />
36. Wit, J. d & Andersen, S. D. 2003. Emissioner fra større gasfyrede kedler, Dansk Gasteknisk Center 2003. The emission factor<br />
have been assumed to be <strong>the</strong> average value of <strong>the</strong> stated interval (NERI assumption).<br />
37. Folkecenter for Vedvarende Energi, 2000. http://www.folkecenter.dk/plant-oil/emission/emission_rapsolie.pdf<br />
38. Assumed same emission factor as for gas oil (NERI assumption). However <strong>the</strong> value is not correct – <strong>the</strong> emission factor 65 g/GJ<br />
will be applied in future inventories.<br />
Time-series for emission factors for SO 2 , NO X , NMVOC and CO that are not <strong>the</strong> same<br />
in 1990-2003 are shown below. All o<strong>the</strong>r factors are constant in 1990-2003.<br />
Table 3A-35 SO 2 , NO X , NMVOC and CO emission factors time-series [g/GJ].<br />
<br />
SO2 COAL 0101 1A1a 506 571 454 386<br />
SO2 COAL 010101 1A1a 506 571 454 386 343 312 420 215 263 193 64 47 45 61<br />
SO2 COAL 010102 1A1a 506 571 454 386 343 312 420 215 263 193 64 47 45 61<br />
SO2 COAL 010103 1A1a 343 312 420 215 263 193 64 47 45 61<br />
SO2 COAL 010104 1A1a 343 312 420 215<br />
SO2 COAL 0102 1A1a 574 574 574 574 574 574 574 574<br />
SO2 COAL 0201 1A4a 574 574 574 574 574 574 574 574 574<br />
SO2 COAL 0202 1A4b 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 COAL 0203 1A4c 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 COAL 0301 1A2f 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 BROWN COAL BRI. 0201 1A4a 574 574 574 574 574 574 574<br />
SO2 BROWN COAL BRI. 0202 1A4b 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 BROWN COAL BRI. 0203 1A4c 574 574 574 574 574 574 574 574 574<br />
SO2 BROWN COAL BRI. 0301 1A2f 574 574 574 574 574 574 574 574<br />
SO2 COKE OVEN COKE 0202 1A4b 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 COKE OVEN COKE 0301 1A2f 574 574 574 574 574 574 574 574 574 574 574 574 574 574<br />
SO2 PETROLEUM COKE 0201 1A4a 787 787 787 787 787 787 787 787 787 787 787 605 605 605<br />
SO2 PETROLEUM COKE 0202 1A4b 787 787 787 787 787 787 787 787 787 787 787 605 605 605<br />
SO2 PETROLEUM COKE 0203 1A4c 787 787 787 787 787 787 787 787 787 787 787 605 605 605<br />
SO2 PETROLEUM COKE 0301 1A2f 787 787 787 787 787 787 787 787 787 787 787 605 605 605<br />
SO2 MUNICIP. WASTES 0101 1A1a 116 116 95 73<br />
SO2 MUNICIP. WASTES 010102 1A1a 116 95 73 52 30 26 25 23,9 23,9 23,9 23,9<br />
SO2 MUNICIP. WASTES 010103 1A1a 52 30 29 28 26 25 23,9 23,9 23,9 23,9<br />
SO2 MUNICIP. WASTES 010104 1A1a 52 30 29 28 26 25 23,9 23,9 23,9 23,9<br />
289