OECD SIDS<br />

N-(1,3-DIMETHYLBUTYL)-N´-PHENYL-1,4-PHENYLENEDIAMINE<br />

4. ECOTOXICITY ID: 793-24-8<br />

DATE: 11.05.2005<br />

Analytical monitoring : No<br />

Method : other<br />

Year : 1976<br />

GLP : No<br />

Test substance : other TS: Santoflex 13<br />

Method : Monsanto Standard Protocol Oct. 1976<br />

Remark : Test substance concentration not monitored during exposure;<br />

due to the instability of the TS in aqueous solution, the effective TS<br />

concentrations are expected to be lower than the applied nominal<br />

concentrations.<br />

Very low oxygen concentration at the end of incubation<br />

Result : Confidence interval for 96 h LC50 = 0.32 - 0.50 mg/l<br />

24 h LC50 = 0.65 mg/l (0.41 - 1.0 mg/l)<br />

48 h LC50 = 0.45 mg/l (0.31 - 0.65 mg/l)<br />

Test condition : - Carrier: acetone<br />

- 15 l water in all glass vessels, 10 fish per vessel<br />

- Fish length 3.8 cm<br />

- Fish not fed 48 h prior to exposure, nor during exposure<br />

- No aeration oxygen ranged from 8.6 mg/l (98 % saturation) to 0.2 mg/l (2<br />

% saturation) at the beginning and end of exposure, respectively<br />

- Temperature 22 +/- 1 °C<br />

- pH ranged from 7.2 initially to 6.7 at the end of the test<br />

- Observations and mortality counts were made every 24 h following<br />

initiation of exposure<br />

- Statistics: least squares regression analysis to calculate LC 50 and 95 %<br />

confidence intervals<br />

Test substance : Santoflex (KDO3-017) CP-22423, dark red-brown colored<br />

Reliability : (3) invalid<br />

Significant methodological deficiencies<br />

04.11.2004 (49)<br />

Type : Static<br />

Species : Salmo gairdneri (Fish, estuary, fresh water)<br />

Exposure period : 96 hour(s)<br />

Unit : mg/l<br />

LC50 : = .14<br />

Limit test :<br />

Analytical monitoring : No<br />

Method : other<br />

Year : 1976<br />

GLP : No<br />

Test substance : other TS: Santoflex 13<br />

Method : Monsanto Standard Protocol Oct. 1976<br />

Remark : Test substance concentration not monitored during exposure;<br />

due to the instability of the TS in aqueous solution, the effective TS<br />

concentrations are expected to be lower than the applied nominal<br />

concentrations<br />

Result : Confidence interval for 96 h LC50 = 0.12 - 0.16 mg/l<br />

24 h LC50 = 0.28 mg/l (0.21 - 0.36 mg/l)<br />

48 h LC50 = 0.18 mg/l (0.16 - 0.20 mg/l)<br />

Test condition : - Carrier: acetone<br />

- 15 l water in all glass vessels, 10 fish per vessel<br />

- Fish length 3.7 cm<br />

- Fish not fed 48 h prior to exposure, nor during exposure<br />

- No aeration oxygen ranged from 9.0 mg/l (93% saturation) to 2.8 mg/l (26<br />

% of saturation) at the beginning and end of exposure, respectively<br />

- Temperature 12 +/- 1 °C<br />

- pH ranged from 7.0 initially to 6.8 at the end of the test<br />

- Observations and mortality counts were made every 24 h following<br />

UNEP PUBLICATIONS 81