Main Sub<br />
code code<br />
66 03 FAX PWB memory check<br />
(Executable only when the<br />
FAX is installed.)<br />
Contents Details of function/operation<br />
04 Signal send mode (Max.<br />
value) (Executable only<br />
when the FAX is installed.)<br />
[Function]<br />
Use to check the FAX PWB memory.<br />
[Operation]<br />
1) Initial display<br />
SELECT CHECK MEMORY<br />
PRESS ←, →<br />
2) [ ] [ ] key or after 2sec<br />
Every time when [<br />
→ 2 → 3 → 1.<br />
] key is pressed, the second line is changed in the sequence of No. 1<br />
When [ ] key is pressed, the sequence is reversed.<br />
SELECT MEMORY (1-3)<br />
1:DRAM<br />
∗ [Cle<strong>ar</strong>] key: FAX control is terminated.<br />
3) [OK]/[ENTER] key<br />
CHECKING MEMORY<br />
4) After completion of check<br />
When the result is OK<br />
MEMORY CHECK RESULT<br />
OK<br />
In case of sum check error<br />
MEMORY CHECK RESULT<br />
XXXXXXXX SUM NG<br />
∗ [Cle<strong>ar</strong>] key: Returns to "1) Initial display".<br />
[Function]<br />
Use to set the signal send mode (Max. value).<br />
Facsimile simulation design specifications.<br />
[Operation]<br />
1) Initial display<br />
SELECT MEMORY (1-3)<br />
2:SRAM<br />
In case of address bus<br />
check error<br />
MEMORY CHECK RESULT<br />
XXXXXXXX A-BUS NG<br />
In case of data check error<br />
MEMORY CHECK RESULT<br />
XXXXXXXX DATA NG<br />
AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 34<br />
SELECT MEMORY (1-3)<br />
3:FLASH<br />
In case of data bus check<br />
error<br />
MEMORY CHECK RESULT<br />
XXXXXXXX D-BUS NG<br />
In case of erase check error<br />
MEMORY CHECK RESULT<br />
XXXXXXXX ERASE NG<br />
1 NO SIGNAL 13 7200bps(V34) 25 2400bps(V27ter)<br />
2 33600bps(V34) 14 4800bps(V34) 26 300bps(FLAG)<br />
3 31200bps(V34) 15 2400bps(V34) 27 2100Hz(CED)<br />
4 28800bps(V34) 16 14400bps(V33) 28 1100Hz(CNG)<br />
5 26400bps(V34) 17 12000bps(V33) 29 300bps(V21)<br />
6 24000bps(V34) 18 14400bps(V17) 30 2100Hz(ANSam)<br />
7 21600bps(V34) 19 12000bps(V17) 31 DUMMY RING<br />
8 19200bps(V34) 20 9600bps(V17) 32 NO VOICE ANSWER<br />
9 16800bps(V34) 21 7200bps(V17) 33 NO RING BACK TONE<br />
10 14400bps(V34) 22 9600bps(V29) 34 LINE OFF HOOK<br />
11 12000bps(V34) 23 7200bps(V29) 35 LINE ON HOOK<br />
12 9600bps(V34) 24 4800bps(V27ter)<br />
SELECT OUTPUT SIGNAL<br />
(2 DIGITS) No.___<br />
2) 2-digit (1-35) with [Numeric] key / [ ] [ ] key / 2sec after<br />
Pressing [ ] key or [ ] key reverses the sequence.<br />
No. (1-35)<br />
1:NO SIGNAL<br />
∗ [Cle<strong>ar</strong>] key: FAX control is terminated.<br />
3) [OK]/[ENTER] key: Send after setting<br />
OUTPUTING SIGNAL MAX<br />
PRESS CLEAR TO STOP<br />
∗ [Cle<strong>ar</strong>] key: Returns to "1) Initial display".<br />
..... No. (1-35)<br />
35:LINE ON HOOK