24 15 Scanner mode counter cle<strong>ar</strong><br />
(AR-203E/M200/M201)<br />
25 01 Main motor operation check<br />
(Cooling fan motor rotation<br />
check)<br />
Contents Details of function/operation<br />
[Function]<br />
When [OK]/[ENTER]/[START] key is pressed, the scanner mode counter value is cle<strong>ar</strong>ed to 0,<br />
and "000,000" is displayed on the LCD/display.<br />
[Operation]<br />
AR-M200/M201<br />
1) Initial display<br />
24-15 S-MODE CLR.<br />
CLEARED 000,000<br />
[Function]<br />
When [OK]/[ENTER]/[START] key is pressed, the main motor (and the duplex motor in the case<br />
of a duplex <strong>model</strong>) is operated for 30sec.<br />
To reduce toner consumption, if the developing unit is installed, the developing bias, the main<br />
ch<strong>ar</strong>ger, and the grid <strong>ar</strong>e also outputted.<br />
In this case, laser disch<strong>ar</strong>ge is required when stopping the motor, the polygon motor is also<br />
operated at the same time. Check for installation of the developing unit. If it is not installed, the<br />
high voltage above is not outputted and only the motor is rotated.<br />
To check the developing bias, install the developing unit.<br />
After completion of 30sec operation, the machine goes into the sub code entry standby mode.<br />
[Operation] (AR-M200/M201)<br />
1) Initial display<br />
25-01 MAIN MOTOR CHK<br />
EXECUTING...<br />
10 Polygon motor ON [Function]<br />
When [OK]/[ENTER]/[START] key is pressed, the Bios is called to rotate the polygon motor for<br />
30sec.<br />
After completion of 30sec operation, the operation is turned off with the Bios and the machine<br />
goes into the sub code entry standby mode.<br />
[Operation] (AR-M200/M201)<br />
1) Initial display<br />
25-10 LSU CHK<br />
EXECUTING...<br />
26 02 SPF/RSPF setup [Function]<br />
When this simulation is executed, the current set SPF/RSPF is displayed. Enter the code number<br />
corresponding to the desired SPF/RSPF and press [OK]/[ENTER]/[START] key to save the<br />
setting.<br />
Code number SPF/RSPF Display item<br />
0 SPF NO SPF OFF<br />
1 SPF YES SPF ON<br />
2 RSPF YES RSPF ON<br />
For the AR-203E/<strong>5420</strong>, the code number cannot be set to 2.<br />
For the AR-M200/M201, the code number cannot be set to 1.<br />
[Operation]<br />
AR-M200/M201<br />
1) The current set value is<br />
displayed.<br />
26-02 SPF/RSPF<br />
1:SPF ON (0- 2)<br />
2) [Numeric] key or [ ] key<br />
26-02 SPF/RSPF<br />
0:SPF OFF (0- 2)<br />
03 Second cassette setup [Function]<br />
When this simulation is executed, the current set second cassette is displayed. Enter the code<br />
number corresponding to the desired second cassette and press [OK]/[ENTER]/[START] key to<br />
save the setting.<br />
[Operation]<br />
The operation is simil<strong>ar</strong> to simulation 26-02.<br />
2) [Numeric] key or [ ] key<br />
26-02 SPF/RSPF<br />
2:RSPF ON (0- 2)<br />
3) [OK]/[ENTER]/[START]<br />
key<br />
26-02 SPF/RSPF<br />
2:RSPF ON (0- 2)<br />
AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 13<br />
AR-203E<br />
The operation is simil<strong>ar</strong> to simulation 20-01.<br />
Code number Second cassette Display item<br />
0 Second cassette NO OFF<br />
1 Second cassette YES ON<br />
For the AR-203E/<strong>5420</strong>/M200/M201, the code number cannot be set to 1.<br />
AR-203E/<strong>5420</strong><br />
1) Press [ ] [ ] key to<br />
2)<br />
change the code number.<br />
Press [START] key to fix<br />
the code number.