[10] SIMULATION, TROUBLE CODES<br />
1. Entering the simulation mode<br />
To enter the <strong>service</strong>man simulation mode, press the keys as follows:<br />
AR-203E/AR-<strong>5420</strong><br />
[Cle<strong>ar</strong>] key → Exposure mode selector key → [Cle<strong>ar</strong>] key →<br />
Exposure mode selector key<br />
AR-M200/AR-M201<br />
[#] key → [∗] key → [Cle<strong>ar</strong>] key → [∗] key<br />
To cancel the simulation mode, press the [Cle<strong>ar</strong> All] key.<br />
2. Key rule<br />
AR-203E/AR-<strong>5420</strong><br />
[ ] [ ] key: Entry of MAIN CODE/SUB CODE<br />
Setting of the adjustment values for the<br />
adjustment-related simulations<br />
When [%] key is pressed simultaneously, the<br />
value is displayed in the descending<br />
sequence such as [0] → [9], not as [0] → [1].<br />
[START] key: Settlement<br />
<br />
[START] key: Settlement / Print<br />
[Exposure mode<br />
selector] key: Selection of an item<br />
[Cle<strong>ar</strong>] key: (Interrupting operation check) Returns to the<br />
upper hier<strong>ar</strong>chy.<br />
On the initial display (00-00), it terminates the<br />
simulation.<br />
Exits from the simulation mode.<br />
For a simulation of adjustment, the display<br />
returns to the initial display (00-00).<br />
AR-M200/AR-M201<br />
[Numeric] key: Entry of MAIN CODE/SUB CODE<br />
Selection of an item<br />
Setup of an adjustment value in case of<br />
simulations for adjustment<br />
[ ] [ ] key: Selection of MAIN CODE/SUB CODE<br />
Selection of an item<br />
[OK]/[ENTER]/<br />
[START] key: Settlement<br />
<br />
[OK]/[ENTER] key: Settlement (Without print)<br />
[START] key: Settlement / Print<br />
[Cle<strong>ar</strong>] key: (Interrupting operation check) Returns to the<br />
upper hier<strong>ar</strong>chy.<br />
In case of simulation of operation check,<br />
terminates the operations.<br />
[Cle<strong>ar</strong> All] key: Exits from the simulation mode.<br />
For a simulation of adjustment, the display<br />
returns to the initial display (00-00).<br />
3. List of simulations<br />
Sim<br />
No.<br />
Sub<br />
code<br />
Operation<br />
01 01 Mirror scan operation<br />
02 Mirror home position sensor (MHPS) status display<br />
06 Aging of mirror scanning<br />
02 01 SPF/RSPF aging operation (Only the AR-203E/<br />
M200/M201 with the SPF/RSPF installed)<br />
02 SPF/RSPF sensor status display (Only the<br />
AR-203E/M200/M201 with the SPF/RSPF installed)<br />
AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 1<br />
Sim<br />
No.<br />
Sub<br />
code<br />
Operation<br />
02 03 SPF/RSPF Motor ON (Only the AR-203E/M200/<br />
M201 with the SPF/RSPF installed)<br />
06 Resist clutch ON (SPF) (AR-203E only)<br />
08 RSPF paper feed solenoid operation check<br />
(Only the AR-M200/M201 with the RSPF installed)<br />
09 RSPF reverse solenoid operation check<br />
(Only the AR-M200/M201 with the RSPF installed)<br />
03 03 Shifter operation check (AR-M200/M201)<br />
05 01 Operation panel display check<br />
02 Fusing lamp, cooling fan operation check<br />
03 Copy lamp ON<br />
06 01 Paper feed solenoid ON<br />
02 Resist solenoid ON<br />
07 01 W<strong>ar</strong>m-up display and aging with jam<br />
06 Intermittent aging<br />
08 Shift to copy with the w<strong>ar</strong>m-up display<br />
08 01 Developing bias<br />
02 Main ch<strong>ar</strong>ger (Grid high)<br />
03 Grid voltage (Low)<br />
06 Transfer ch<strong>ar</strong>ger<br />
09 01 Duplex motor normal rotation operation check<br />
(AR-M201 only)<br />
02 Duplex motor reverse operation check<br />
(AR-M201 only)<br />
04 Duplex motor rotation speed adjustment<br />
(AR-M201 only)<br />
10 Toner motor aging<br />
14 Cancel of troubles other than U2<br />
16 Cancel of U2 trouble<br />
20 01 Maintenance counter cle<strong>ar</strong><br />
21 01 Maintenance cycle setting<br />
22 01 Maintenance counter display<br />
02 Maintenance preset display<br />
04 JAM total counter display<br />
05 Total counter display<br />
06 Developer counter display<br />
08 SPF/RSPF counter display (Only the AR-203E/<br />
M200/M201 with the SPF/RSPF installed)<br />
11 FAX-related counter display<br />
(Executable only when the FAX is installed.)<br />
12 Drum counter display<br />
13 CRUM type display<br />
14 ROM version display<br />
16 Duplex counter display (AR-M201 only)<br />
17 Copy counter display<br />
18 Printer counter display<br />
19 Scanner mode counter display<br />
(AR-203E/M200/M201)<br />
21 Scanner counter display<br />
22 SPF/RSPF JAM counter display (Only the<br />
AR-203E/M200/M201 with the SPF/RSPF installed)<br />
24 01 JAM total counter cle<strong>ar</strong><br />
04 SPF/RSPF counter cle<strong>ar</strong> (Only the AR-203E/<br />
M200/M201 with the SPF/RSPF installed)<br />
05 Duplex counter cle<strong>ar</strong> (AR-M201 only)<br />
06 Developer counter cle<strong>ar</strong><br />
07 Drum counter cle<strong>ar</strong><br />
08 Copy counter cle<strong>ar</strong><br />
09 Printer counter cle<strong>ar</strong><br />
10 FAX counter cle<strong>ar</strong><br />
(Executable only when the FAX is installed.)<br />
13 Scanner counter cle<strong>ar</strong><br />
14 SPF/RSPF JAM total counter cle<strong>ar</strong> (Only the<br />
AR-203E/M200/M201 with the SPF/RSPF installed)