service manual ar-203e ar-203e x ar-m200 ar-m201 model ar-5420
service manual ar-203e ar-203e x ar-m200 ar-m201 model ar-5420
service manual ar-203e ar-203e x ar-m200 ar-m201 model ar-5420
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Main Sub<br />
code code<br />
02 02 SPF/RSPF sensor status<br />
display (Only the AR-203E/<br />
M200/M201 with the<br />
SPF/RSPF installed)<br />
03 SPF/RSPF Motor ON<br />
(Only the AR-203E/M200/<br />
M201 with the SPF/RSPF<br />
installed)<br />
06 Resist clutch ON (SPF)<br />
(AR-203E only)<br />
08 RSPF paper feed solenoid<br />
operation check<br />
(Only the AR-M200/M201<br />
with the RSPF installed)<br />
09 RSPF reverse solenoid<br />
operation check<br />
(Only the AR-M200/M201<br />
with the RSPF installed)<br />
03 03 Shifter operation check<br />
(AR-M200/M201)<br />
Contents Details of function/operation<br />
[Function]<br />
The ON/OFF status of the SPF/RSPF sensors can be checked with the LCD/LED.<br />
When a sensor is ON, the sensor name is displayed on the LCD/LED.<br />
Sensor<br />
Display item<br />
(AR-M200/M201)<br />
Display item<br />
(AR-203E)<br />
Document set sensor SPID TD c<strong>ar</strong>tridge replacement required<br />
lamp<br />
RSPF document transport sensor SPPD Misfeed lamp<br />
RSPF paper feed cover open/close<br />
sensor<br />
SDSW —<br />
RSPF paper exit sensor SPOD —<br />
[Operation] (AR-M200/M201)<br />
1) Initial display 2) When the sensor is ON:<br />
02-02 SPF SENSOR 02-02 SPF SENSOR<br />
SPID SPPD SDSW SPOD<br />
[Function]<br />
When [OK]/[ENTER]/[START] key is pressed, the motor rotates for 10sec at the speed corresponding<br />
to the set magnification ratio.<br />
[Operation] (AR-M200/M201)<br />
The operation is simil<strong>ar</strong> to simulation 01-01.<br />
When the [START] key is pressed, the SPF resist clutch (SRRC) repeats ON (500 ms) and OFF<br />
(500 ms) 20 times.<br />
[Function]<br />
The RSPF paper feed solenoid (SPUS) repeats ON for 500ms and OFF for 500ms 20 times by<br />
the use of the solenoid drive control Bios.<br />
[Operation]<br />
1) Initial display<br />
02-08 SPF SPUS CHK<br />
EXECUTING...<br />
[Function]<br />
The RSPF reverse solenoid (SPFS) repeats ON for 500ms and OFF for 500ms 20 times by the<br />
use of the solenoid drive control Bios.<br />
[Operation]<br />
1) Initial display<br />
02-09 RSPF SPFS CHK<br />
EXECUTING...<br />
[Function]<br />
The shifter is moved back and forth in four reciprocations.<br />
[Operation]<br />
1) Initial display<br />
03-03 SHIFTER CHK<br />
EXECUTING...<br />
AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 4