46 12 Density adjustment in the<br />
FAX mode (Collective<br />
adjustment) (Executable<br />
only when the FAX is<br />
installed.)<br />
Contents Details of function/operation<br />
13 FAX mode density<br />
adjustment (Normal text)<br />
(Executable only when the<br />
FAX is installed.)<br />
14 FAX mode density<br />
adjustment (Fine text)<br />
(Executable only when the<br />
FAX is installed.)<br />
[Function]<br />
When [START] key is pressed, scan is executed with the entered exposure adjustment value<br />
and the data stored on the FAX side is rewritten into the entered value.<br />
All data of the exposure adjustment values <strong>ar</strong>e rewritten into the same value.<br />
For the density adjustment table data, refer to simulation 46-13 (density adjustment (Normal<br />
text) in the FAX mode).<br />
[Operation]<br />
1) Initial display<br />
ADJUST EXP. AUTO<br />
XX<br />
("XX" is the exposure adjustment value of<br />
normal text stored on the FAX side.)<br />
2) Enter a 2-digit value as the exposure<br />
adjustment value.<br />
ADJUST EXP. AUTO<br />
YY<br />
("YY" is the entered exposure adjustment<br />
value.)<br />
[Function]<br />
Scan is st<strong>ar</strong>ted with the exposure adjustment value entered with [START] key, and the stored<br />
data of the selected mode on the FAX side is rewritten into the input value.<br />
Density adjustment value data table<br />
Mode Photo Exposure adjustment value<br />
STD (Normal text) off<br />
Fine (Fine text) on<br />
off<br />
Sfine (Super fine) on<br />
off<br />
When initializing each data: 50<br />
[Operation]<br />
1) Initial display<br />
ADJUST EXP. STD<br />
XX<br />
("XX" is the corresponding exposure adjustment<br />
value of normal text mode stored on the<br />
FAX side.)<br />
2) Enter a 2-digit value as the exposure<br />
adjustment value with [Numeric] key.<br />
ADJUST EXP. STD<br />
YY<br />
("YY" is the entered exposure adjustment<br />
value.)<br />
[Function]<br />
When [START] key is pressed, scan is st<strong>ar</strong>ted with the entered exposure adjustment value and<br />
the data of the selected mode on the FAX side is changed to the entered value.<br />
For the density adjustment value table data, refer to simulation 46-13 (FAX mode density<br />
adjustment (Normal text).)<br />
[Operation]<br />
1) Initial display<br />
3) Scan st<strong>ar</strong>t (self print)<br />
ADJUST EXP. FINE<br />
XX<br />
("XX" is the corresponding exposure adjustment<br />
value of the fine text mode stored on<br />
the FAX side.)<br />
2) Enter a 2-digit value as the exposure<br />
adjustment value with [Numeric] key.<br />
ADJUST EXP. FINE<br />
YY<br />
("YY" is the entered exposure adjustment<br />
value.)<br />
AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 20<br />
3) Scan is st<strong>ar</strong>ted (self print), and the LED<br />
of [START] key is turned off.<br />
ADJUST EXP. AUTO<br />
SCAN YY<br />
4) Print is st<strong>ar</strong>ted (self print).<br />
ADJUST EXP. AUTO<br />
PRINT YY<br />
After completion of printing, returns to “2)”<br />
display.<br />
3) Scan is st<strong>ar</strong>ted (self print), and the LED<br />
of [START] key is turned off.<br />
ADJUST EXP. STD<br />
SCAN YY<br />
4) Print is st<strong>ar</strong>ted (self print).<br />
ADJUST EXP. STD<br />
PRINT YY<br />
After completion of printing, returns to “2)”<br />
display.<br />
ADJUST EXP. FINE<br />
SCAN YY<br />
4) Print st<strong>ar</strong>t (self print)<br />
ADJUST EXP. AUTO<br />
PRINT YY<br />
After completion of printing, returns to “2)”<br />