Main Sub<br />

code code<br />

66 11 300bps signal send (Max.<br />

value) (Executable only<br />

when the FAX is installed.)<br />

Contents Details of function/operation<br />

12 300bps signal send (Soft<br />

SW set value) (Executable<br />

only when the FAX is<br />

installed.)<br />

[Function]<br />

Use to set the 300bps signal send (Max. value).<br />

1: NO SIGNAL<br />

2: 11111<br />

3: 11110<br />

4: 00000<br />

5: 010101<br />

6: 00001<br />

[Operation]<br />

1) Initial display<br />

SELECT SIGNAL<br />

PRESS ←, →<br />

2) [ ] [ ] key or after 2sec<br />

Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1<br />

→ 2 → 3 → 4 → 5 → 6 → 1.<br />

When [ ] key is pressed, the sequence is reversed.<br />

SELECT SIGNAL (1-6)<br />

1:NO SIGNAL<br />

∗ [Cle<strong>ar</strong>] key: FAX control is terminated.<br />

3) [OK]/[ENTER] key<br />

OUTPUTING SIGNAL MAX<br />

PRESS CLEAR TO STOP<br />

∗ [Cle<strong>ar</strong>] key: Returns to "1) Initial display".<br />

..... SELECT SIGNAL (1-6)<br />

6:00001<br />

[Function]<br />

Use to set the 300bps signal send (Soft SW set value).<br />

1: NO SIGNAL<br />

2: 11111<br />

3: 11110<br />

4: 00000<br />

5: 010101<br />

6: 00001<br />

[Operation]<br />

1) Initial display<br />

SELECT SIGNAL<br />

PRESS ←, →<br />

2) [ ] [ ] key or after 2sec<br />

Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1<br />

→ 2 → 3 → 4 → 5 → 6 → 1.<br />

When [ ] key is pressed, the sequence is reversed.<br />

SELECT SIGNAL (1-6)<br />

1:NO SIGNAL<br />

∗ [Cle<strong>ar</strong>] key: FAX control is terminated.<br />

3) [OK]/[ENTER] key<br />

OUTPUTING SIGNAL SSW<br />

PRESS CLEAR TO STOP<br />

∗ [Cle<strong>ar</strong>] key: Returns to "1) Initial display".<br />

..... SELECT SIGNAL (1-6)<br />

6:00001<br />

AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 36