Contents Details of function/operation<br />

08 01 Developing bias [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the developing bias signal is turned ON for 30sec.<br />

When, however, an actual output value is measured, use simulation 25-01.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation] (AR-M200/M201)<br />

02 Main ch<strong>ar</strong>ger (Grid high) [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the main ch<strong>ar</strong>ger is outputted for 30sec in the grid<br />

voltage HIGH move.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation] (AR-M200/M201)<br />

1) Initial display<br />

08-02 MHV(H) SET.<br />

EXECUTING...<br />

03 Grid voltage (Low) [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the main ch<strong>ar</strong>ger is outputted for 30sec in the grid<br />

voltage LOW move.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation] (AR-M200/M201)<br />

1) Initial display<br />

08-03 MHV(L) SET.<br />

EXECUTING...<br />

06 Transfer ch<strong>ar</strong>ger [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the transfer ch<strong>ar</strong>ger is outputted for 30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation] (AR-M200/M201)<br />

1) Initial display<br />

08-06 THV SET.<br />

EXECUTING...<br />

09 01 Duplex motor normal<br />

rotation operation check<br />

(AR-M201 only)<br />

02 Duplex motor reverse<br />

operation check<br />

(AR-M201 only)<br />

04 Duplex motor rotation speed<br />

adjustment (AR-M201 only)<br />

1) Initial display<br />

08-01 DVLP BIAS SET.<br />

EXECUTING...<br />

[Function]<br />

Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction)<br />

for 30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

09-01 DPLX ROT.<br />

EXECUTING...<br />

[Function]<br />

Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

09-02 DPLX ROT.REV.<br />

EXECUTING...<br />

[Function]<br />

When this simulation is executed, the currently set value is displayed.<br />

Enter the adjustment value with [Numeric] key and press [OK]/[ENTER]/[START] key. The<br />

entered value is stored and the machine goes into the sub code entry standby mode. The<br />

greater the set value is, the higher the speed is. The smaller the set value is, the lower the<br />

speed is. (Setting range: 1 - 13, Default: 8)<br />

[Operation]<br />

1) Initial display 2) [Numeric] key 3) [OK]/[ENTER]/[START]<br />

09-04 DPLX ROT.SPEED<br />

8( 1-13)<br />

AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 7<br />

09-04 DPLX ROT.SPEED<br />

key<br />

7( 1-13) 09-04 DPLX ROT.SPEED<br />

7( 1-13)