4. Descriptions of v<strong>ar</strong>ious simulations<br />

Main<br />

code<br />

Sub<br />

code<br />

Contents Details of function/operation<br />

01 01 Mirror scan operation [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the home position is checked and the mirror base<br />

performs full scan at the speed of the set magnification ratio.<br />

During operation, the set magnification ratio is displayed.<br />

The mirror home position sensor status is displayed with the "Drum replacement required lamp<br />

(or the copy mode indicator for the AR-M200/M201)". (When the mirror is in the home position,<br />

the lamp lights up.)<br />

During operation, the copy lamp lights up.<br />

When [Cle<strong>ar</strong>] key is pressed, if the operation is on the way, it is terminated and the machine<br />

goes to the sub code entry standby mode.<br />

[Operation] (AR-M200/M201)<br />

1) Initial display 2) [ZOOM]/[COPY RATIO] 3) [OK]/[ENTER]/[START]<br />

01-01 SCAN CHK<br />

key<br />

key<br />

- 100% + 01-01 SCAN CHK<br />

01-01 SCAN CHK<br />

- 78% + EXECUTING... - 78% +<br />

02 Mirror home position sensor<br />

(MHPS) status display<br />

[Function]<br />

Monitors the mirror home position sensor, and makes the "Drum replacement required lamp (or<br />

the copy mode indicator for the AR-M200/M201)" turn on during the sensor ON status.<br />

[Operation] (AR-M200/M201)<br />

1) Initial display<br />

06 Aging of mirror scanning [Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the mirror base performs full scan at the speed of<br />

the set magnification ratio.<br />

During operation, the set magnification ratio is displayed.<br />

After 3sec, the mirror base performs full scan again.<br />

∗ When [OK]/[ENTER]/[START] key is pressed once, the ready lamp remains OFF.<br />

The mirror home position sensor status is displayed on the "Drum replacement required lamp<br />

(or the copy mode indicator for the AR-M200/M201)." (The lamp is ON when the mirror is in the<br />

home position.)<br />

During aging, the copy lamp is ON.<br />

[Operation] (AR-M200/M201)<br />

The operation is simil<strong>ar</strong> to simulation 01-01.<br />

02 01 SPF/RSPF aging operation<br />

(Only the AR-203E/M200/<br />

M201 with the SPF/RSPF<br />

installed)<br />

01-02 MHP-SENSOR<br />

EXECUTING...<br />

2) [ ] key<br />

01-01 SCAN CHK<br />

- 99% +<br />

2) [ ] key<br />

01-01 SCAN CHK<br />

- 101% +<br />

[Function]<br />

When [OK]/[ENTER]/[START] key is pressed, the set magnification ratio is obtained. For the<br />

SPF, the single-face document transport is performed. For the RSPF, the duplex document<br />

transport is performed.<br />

However, the operating conditions don't matter and the operation is not stopped even in case of<br />

a jam. Also the magnification ratio is displayed on the LCD/display.<br />

[Operation] (AR-M200/M201)<br />

The operation is simil<strong>ar</strong> to simulation 01-01.<br />

AR-203E/<strong>5420</strong>/M200/M201 SIMULATION, TROUBLE CODES 10 - 3