Long Term Community Plan 2012-2022 - Hurunui District Council
Long Term Community Plan 2012-2022 - Hurunui District Council
Long Term Community Plan 2012-2022 - Hurunui District Council
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
www.hurunui.govt.nz<br />
Levels of Service Water and Sewer<br />
Network<br />
Water Source and<br />
Treatment<br />
Amberley Deep bore in daily use<br />
all year.<br />
No treatment but<br />
looking to prove secure<br />
groundwater status.<br />
Low supply outage risk<br />
Leithfield Beach Deep bore only. No<br />
water treatment<br />
Moderate risk for<br />
outage<br />
Culverden Deep bore with<br />
shallow bore back-up<br />
and chlorine (if needed<br />
for shallow bore). Low<br />
risk of supply outage<br />
Waiau Shallow river bore with<br />
two pumps. uV with<br />
chlorine introduced<br />
when turbidity climbs<br />
Moderate risk<br />
Waipara Two moderate depth<br />
bores with the older<br />
as back-up. No water<br />
treatment. Moderate<br />
risk of supply outage<br />
Hanmer Springs River intake. Low risk<br />
due to open reservoir<br />
storage. Settling pond,<br />
dose aided filtration, uV<br />
& chlorine back-up<br />
Hawarden<br />
Waikari<br />
Moderate depth river<br />
bore with shallow<br />
gallery back-up. Low<br />
risk<br />
LEVELS OF SERVICE – ON-DEMAND (URBAN) WATER NETWORKS – February 2011<br />
Management Documents and Service<br />
Storage Based on<br />
Demand<br />
Hydraulic<br />
Performance<br />
DWSNZ Grading<br />
Warnings and<br />
Compliance<br />
Fire Fightiing Continuity of Supply<br />
Asset Management <strong>Plan</strong> in place<br />
Approved PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Volume - 816m3<br />
% average - 26hrs<br />
% peak - 10hrs<br />
Min flow - 15l/min<br />
Min press . 200kpa<br />
Max press - 650kpa<br />
Sources - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - Yes<br />
Back up generator<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Volume - 120m3<br />
% average - 13hrs<br />
% peak - 4.5hrs<br />
Min flow - 12l/min<br />
Min press . 100kpa<br />
Max press - 580kpa<br />
Source - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - Yes<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - needs<br />
testing<br />
Back up generator<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Asset Management <strong>Plan</strong> in place<br />
Approved PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Asset Management <strong>Plan</strong> in place<br />
PHRMP requires update.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Asset Management <strong>Plan</strong> in place<br />
PHRMP requires update.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Asset Management <strong>Plan</strong> in place<br />
PHRMP drafted.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
Volume - 90m3<br />
% average - 6.5hrs<br />
% peak - 3hrs<br />
Volume - 180m3<br />
% average - 17hrs<br />
% peak - 6.5hrs<br />
Volume - 92m3<br />
% average - 19hrs<br />
% peak - 8hrs<br />
Volume - 92m3<br />
% average - 19hrs<br />
% peak - 8hrs<br />
Volume - 35m3<br />
% average - 16hrs<br />
% peak - 3.5hrs<br />
Min flow - 15l/min<br />
Min press . 200kpa<br />
Max press - 500kpa<br />
Min flow - 12l/min<br />
Min press . 300kpa<br />
Max press - 600kpa<br />
Min flow - 12l/min<br />
Min press . 300kpa<br />
Max press - 600kpa<br />
Min flow - 15l/min<br />
Min press . 300kpa<br />
Max press - 600kpa<br />
Min flow - 12l/min<br />
Min press . 200kpa<br />
Max press - 650kpa<br />
Source - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - Yes<br />
(Ecoli)<br />
Source - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
Source - E<br />
Reticulation - e<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
Source - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
Source - U<br />
Reticulation - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - Yes<br />
(Ecoli)<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - Yes<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - needs<br />
testing<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - needs<br />
testing<br />
U/G hydrants<br />
Meets minimum stds of<br />
12.5l/s @250kpa - Yes<br />
U/G hydrants<br />
Meets minimum stds<br />
of 12.5l/s @250kpa -<br />
needs testing<br />
Back up generator<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Gravity plus back-up diesel pump.<br />
Max planned outage 4 hrs. Supply<br />
active for 98.5% of year, excl<br />
disasters and CD emergencies.<br />
Connection for portable<br />
generator. Max planned outage<br />
4 hrs. Supply active for 98.5%<br />
of year, excl disasters and CD<br />
emergencies.<br />
272