www.hurunui.govt.nz<br />

Levels of Service Water and Sewer<br />

Network<br />

Water Source and<br />

Treatment<br />

Amberley Deep bore in daily use<br />

all year.<br />

No treatment but<br />

looking to prove secure<br />

groundwater status.<br />

Low supply outage risk<br />

Leithfield Beach Deep bore only. No<br />

water treatment<br />

Moderate risk for<br />

outage<br />

Culverden Deep bore with<br />

shallow bore back-up<br />

and chlorine (if needed<br />

for shallow bore). Low<br />

risk of supply outage<br />

Waiau Shallow river bore with<br />

two pumps. uV with<br />

chlorine introduced<br />

when turbidity climbs<br />

Moderate risk<br />

Waipara Two moderate depth<br />

bores with the older<br />

as back-up. No water<br />

treatment. Moderate<br />

risk of supply outage<br />

Hanmer Springs River intake. Low risk<br />

due to open reservoir<br />

storage. Settling pond,<br />

dose aided filtration, uV<br />

& chlorine back-up<br />

Hawarden<br />

Waikari<br />

Moderate depth river<br />

bore with shallow<br />

gallery back-up. Low<br />

risk<br />

LEVELS OF SERVICE – ON-DEMAND (URBAN) WATER NETWORKS – February 2011<br />

Management Documents and Service<br />

Storage Based on<br />

Demand<br />

Hydraulic<br />

Performance<br />

DWSNZ Grading<br />

Warnings and<br />

Compliance<br />

Fire Fightiing Continuity of Supply<br />

Asset Management <strong>Plan</strong> in place<br />

Approved PHRMP.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Volume - 816m3<br />

% average - 26hrs<br />

% peak - 10hrs<br />

Min flow - 15l/min<br />

Min press . 200kpa<br />

Max press - 650kpa<br />

Sources - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - No<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - Yes<br />

Back up generator<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Asset Management <strong>Plan</strong> in place<br />

No PHRMP.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Volume - 120m3<br />

% average - 13hrs<br />

% peak - 4.5hrs<br />

Min flow - 12l/min<br />

Min press . 100kpa<br />

Max press - 580kpa<br />

Source - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - Yes<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - needs<br />

testing<br />

Back up generator<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Asset Management <strong>Plan</strong> in place<br />

No PHRMP.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Asset Management <strong>Plan</strong> in place<br />

Approved PHRMP.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Asset Management <strong>Plan</strong> in place<br />

PHRMP requires update.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Asset Management <strong>Plan</strong> in place<br />

PHRMP requires update.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Asset Management <strong>Plan</strong> in place<br />

PHRMP drafted.<br />

Water Assessments done<br />

<strong>Term</strong>s & Conditions Contract<br />

Dedicated operator for network with full back-up<br />

resources<br />

All hours phone access for faults<br />

Volume - 90m3<br />

% average - 6.5hrs<br />

% peak - 3hrs<br />

Volume - 180m3<br />

% average - 17hrs<br />

% peak - 6.5hrs<br />

Volume - 92m3<br />

% average - 19hrs<br />

% peak - 8hrs<br />

Volume - 92m3<br />

% average - 19hrs<br />

% peak - 8hrs<br />

Volume - 35m3<br />

% average - 16hrs<br />

% peak - 3.5hrs<br />

Min flow - 15l/min<br />

Min press . 200kpa<br />

Max press - 500kpa<br />

Min flow - 12l/min<br />

Min press . 300kpa<br />

Max press - 600kpa<br />

Min flow - 12l/min<br />

Min press . 300kpa<br />

Max press - 600kpa<br />

Min flow - 15l/min<br />

Min press . 300kpa<br />

Max press - 600kpa<br />

Min flow - 12l/min<br />

Min press . 200kpa<br />

Max press - 650kpa<br />

Source - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - Yes<br />

(Ecoli)<br />

Source - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - No<br />

Source - E<br />

Reticulation - e<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - No<br />

Source - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - No<br />

Source - U<br />

Reticulation - u<br />

Warnings by phone,<br />

mail out and local<br />

advertising<br />

Compliance - Yes<br />

(Ecoli)<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - Yes<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - needs<br />

testing<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - needs<br />

testing<br />

U/G hydrants<br />

Meets minimum stds of<br />

12.5l/s @250kpa - Yes<br />

U/G hydrants<br />

Meets minimum stds<br />

of 12.5l/s @250kpa -<br />

needs testing<br />

Back up generator<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Gravity plus back-up diesel pump.<br />

Max planned outage 4 hrs. Supply<br />

active for 98.5% of year, excl<br />

disasters and CD emergencies.<br />

Connection for portable<br />

generator. Max planned outage<br />

4 hrs. Supply active for 98.5%<br />

of year, excl disasters and CD<br />

emergencies.<br />