Long Term Community Plan 2012-2022 - Hurunui District Council
Long Term Community Plan 2012-2022 - Hurunui District Council
Long Term Community Plan 2012-2022 - Hurunui District Council
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Hurunui</strong> <strong>Community</strong> <strong>Long</strong> <strong>Term</strong> <strong>Plan</strong> <strong>2012</strong> - <strong>2022</strong><br />
Network<br />
Water Source and<br />
Treatment<br />
Ashley Shallow bore field Main<br />
Intake.<br />
Deep bore Racecourse<br />
Rd. Deep bores Kowai<br />
& Smiths Road (both<br />
mothballed).<br />
uV at Main Intake. Ion<br />
exchange Kowai &<br />
Smiths. Sand filtration<br />
Kowai<br />
Waiau Shallow river bore. No<br />
water treatment<br />
Amuri Plains Shallow river plain bore<br />
with uV disinfection<br />
Balmoral Stream weir and river<br />
gallery back-up with<br />
chlorine on both<br />
sources<br />
Cheviot Shallow river plain<br />
bores (3). No water<br />
treatment<br />
<strong>Hurunui</strong> Gallery on #1 & Upper<br />
Waitohi. Shallow bores<br />
on Lower Waitohi &<br />
Peaks. Chlorine on<br />
Upper Waitohi. None<br />
elsewhere<br />
LEVELS OF SERVICE – RESTRICTED (RURAL) WATER NETWORKS – February 2011<br />
Management Documents and Service<br />
Storage Based on<br />
Demand<br />
Hydraulic<br />
Performance<br />
DWSNZ Grading<br />
Warnings and<br />
Compliance<br />
Fire Fightiing Continuity of Supply<br />
Asset Management <strong>Plan</strong> in place<br />
PHRMP requires update.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - U<br />
Zone - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
U/G hydrants in some<br />
urban areas. Remainder o/<br />
head fillers<br />
4 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - U<br />
Zone - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
O/head fillers 6 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - U<br />
Zone - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
O/head fillers 4 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - U<br />
Zone - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
O/head fillers 4 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
Asset Management <strong>Plan</strong> in place<br />
Draft PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - E<br />
Zone - e<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - Yes<br />
(Ecoli)<br />
Hydrants in Cheviot town<br />
otherwise o/head fillers<br />
6 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
Asset Management <strong>Plan</strong> in place<br />
No PHRMP.<br />
Water Assessments done<br />
<strong>Term</strong>s & Conditions Contract<br />
Dedicated operator for network with full back-up<br />
resources<br />
All hours phone access for faults<br />
3 days min at<br />
contracted rate of<br />
supply<br />
1800l/day units with<br />
minimum supply<br />
pressure of 200kpa<br />
Source - U<br />
Zone - u<br />
Warnings by phone,<br />
mail out and local<br />
advertising<br />
Compliance - No<br />
O/head fillers 6 hours planned and up to 12<br />
unplanned repairs. Emergencies<br />
not included<br />
273