<strong>MC35i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong>7.13 <strong>AT</strong>S77.13 <strong>AT</strong>S7 <strong>Set</strong> number of seconds to wait for connection completion<strong>AT</strong>S7 specifies the number of seconds the TA will wait for the completion of the call setup when answering ororiginating a data call. Also referred to as "no answer timeout". To put it plainly, this is the time to wait for thecarrier signal. If no carrier signal is received within the specified time, the TA hangs up.SyntaxRead <strong>Command</strong><strong>AT</strong>S7?Response(s)OKWrite <strong>Command</strong><strong>AT</strong>S7=Response(s)OKERRORReference(s) PIN ASC0 MUX1 MUX2 MUX3 LastV.250 ! % % ! ! ! !Parameter Description (num)(&W)(&V) 9/10/08Number of seconds to wait for connection completion000...060 (&F)Notes• <strong>Command</strong> <strong>AT</strong>S7 is only applicable to data calls.• Values greater than 60 cause no error, but will be restored to the maximum value of 60.• The correlation between <strong>AT</strong>S7 and <strong>AT</strong>S0 is important. If the called party has specified a high value for<strong>AT</strong>S0= call setup may fail.Example: Call setup may fail if <strong>AT</strong>S7=30 and <strong>AT</strong>S0=20.<strong>MC35i</strong>_<strong>AT</strong>C_V02.00nConfidential / ReleasedPage 131 of 390