11.07.2015 Views

MC35i AT Command Set

MC35i AT Command Set

MC35i AT Command Set

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MC35i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong>17.4 <strong>AT</strong>^SCTMSelect to enable or disable the presentation of the URCs. Please note that the setting will not be stored uponPower Down, i.e. after restart or reset, the default =0 will be restored. To benefit from the URCs =1 needsto be selected every time you reboot the GSM engine.Optionally, You may define one for which temperature-based switchoff will be deferred. SeeSection 17.4.1, Deferred shutdown for detail.Parameter Description (num)0 (&F)(P) Presentation of URCs is disabled (except for equal to -2 or +2).1 Presentation of URCs is enabled. (num)-2 Below lowest temperature limit (causes immediate switch-off except in casesdescribed in Section 17.4.1, Deferred shutdown)-1 Below low temperature alert limit0 Normal operating temperature1 Above upper temperature alert limit2 Above uppermost temperature limit (causes immediate switch-off except incases described in Section 17.4.1, Deferred shutdown) (num)0 (&F)(P) Suppress output of in test and read command.1 Output in test and read command. (num)Board temperature in Celsius. Is comprised between the lowest temperature limit and the uppermost temperaturelimit. (str) 9/10/08user defined phonenumber for deferred switchoffone phone number (in international format) that can be called even if a critical temperature limit is exceeded.The number will be stored permanently in the ME. Please refer to Section 17.4.1, Deferred shutdown for moreinformation about the deferred temperature switchoff. The phone number must be in international format, i.e. itmust begin with the international access character ''+''.If the use of call modifiers (such as ''G'',''I'' or ''*31#'') is possible when starting a call to , themodifiers must be stored together with the number, and entered every time the number is called. Otherwise, thenumber may not be recognized, so a temperature switchoff will not be deferred by the active call.The maximum length for the number is 41 digits including the mandatory ''+'' sign.If parameter is left out, an already stored number will remain unchanged.If parameter is invalid, an already stored number will be erased.In order to "orderly" erase a number stored previously as , enter an empty string '''' as parametervalue.Notes• Please refer to the "Hardware Interface Description" for specifications on critical temperature ranges.• To avoid damage the module will shut down once the critical temperature is exceeded.For exceptions please refer to Section 17.4.1, Deferred shutdown.The procedure is equivalent to the power-down initiated with <strong>AT</strong>^SMSO.<strong>MC35i</strong>_<strong>AT</strong>C_V02.00nConfidential / ReleasedPage 354 of 390

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!