11.07.2015 Views

MC35i AT Command Set

MC35i AT Command Set

MC35i AT Command Set

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MC35i</strong> <strong>AT</strong> <strong>Command</strong> <strong>Set</strong>2.13 <strong>AT</strong>^SCFG (str)(+CSCS)AutoExec <strong>Command</strong> IndexThis parameter specifies the command storage index. The following table shows the index ranges supported foreach variant of .Value will be saved while switching off the <strong>MC35i</strong> via <strong>AT</strong> commands (e.g. <strong>AT</strong>+CFUN or <strong>AT</strong>^SMSO) and restoredon next power up. value event Valid Indices0 Autoexec activity is driven by ASC0 DTR 0line activation1 Autoexec activity is timer driven. 0-2 (str)(+CSCS)AutoExec <strong>Command</strong> Mode0...255This parameter specifies details regarding the behavior of the <strong>MC35i</strong> when the <strong>AT</strong> command starts to be executed.Value is interpreted as a bit field, unused bits are reserved for future use (RFU) and shall be set to 0.When a call is released by an Autoexec activity, no release indication may be issued on the first logical channel.If during a data call the <strong>MC35i</strong> temporarily enters command mode via +++ no <strong>AT</strong> command will be executed if specifies 'Ignore ongoing calls'.Value will be saved while switching off the <strong>MC35i</strong> via <strong>AT</strong> commands (e.g. <strong>AT</strong>+CFUN or <strong>AT</strong>^SMSO) and restoredon next power up.Bit Mask hex Mask dec ControlD 0D 10x000x010x020x03012300: Ignore ongoing calls01: Wait until all calls have ended10: Dismiss any ongoing call11: RFUD 2 0x04 4 0: One shot action1: Periodic action (for "AutoExec/Period" only)D 3 0x08 8 RFUD 4 0x10 16 RFUD 5 0x20 32 RFUD 6 0x40 64 RFUD 7 0x80 128 RFU (str)(+CSCS) 9/10/08AutoExec <strong>AT</strong> command StringThis parameter specifies the <strong>AT</strong> command(s) to be launched automatically. Each <strong>AT</strong> command is executed inthe same way as if it were entered online, this means that command concatenation is possible if supported bythe given commands. If serial multiplex mode is activated (<strong>AT</strong>+CMUX) the first logical channel is used, i.e. CSDcalls (data or fax) could be set up. If the <strong>MC35i</strong> is busy on the serial channel command execution will be delayeduntil ongoing action is finished.The first two characters of the automatically launched <strong>AT</strong> command shall be "at" and its length shall be less than25 characters.Please refer to examples below.Value will be saved while switching off the <strong>MC35i</strong> via <strong>AT</strong> commands (e.g. <strong>AT</strong>+CFUN or <strong>AT</strong>^SMSO) and restoredon next power up.<strong>MC35i</strong>_<strong>AT</strong>C_V02.00nConfidential / ReleasedPage 50 of 390

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!