<strong>Analyzer</strong> Operation<br />

Default Operator Action Scrolling Marquee Main Display Notes<br />

HOLD<br />

Press to set the hold time<br />

Thermo Scientific <strong>Orion</strong> <strong>2117HL</strong> <strong>High</strong> <strong>Level</strong> <strong>Chloride</strong> <strong>Analyzer</strong> <strong>User</strong> <strong>Guide</strong><br />

HOLD<br />

(flashing)<br />

00:30 ENTER HOLD TIME<br />

HOUR/MINUTE<br />

Press / to set the first digit<br />

Press to move to the next digit<br />

Press / to set the values of<br />

the remaining digits and press to<br />

move through the remaining digits<br />

Press to accept the setting and<br />

advance to the next screen<br />

ENTER HOLD TIME<br />

HOUR/MINUTE<br />

LASt ENTER HOLD STATE LAST<br />

OR USER VALUE<br />

Press / to scroll between<br />

LASt and USEr<br />

Press to accept the setting and<br />

advance to the next screen<br />

ENTER HOLD STATE LAST<br />

OR USER VALUE<br />

21.0 ENTER FIXED USER VALUE<br />

IN mA<br />

Press / to set the first digit<br />

Press to move to the next digit<br />

Press / to set the values of<br />

the remaining digits and press to<br />

move through the remaining digits<br />

Press to accept the setting and<br />

advance to the next screen<br />

ENTER FIXED USER VALUE<br />

IN mA<br />

OFF HOLD TO 22mA WHEN ERROR OFF<br />

Press / to scroll between<br />

OFF and On<br />

SEL<br />

SCrn<br />

# # : # #<br />

(first digit flashing)<br />

# # : # #<br />

(change flashing digit)<br />

LASt<br />

(flashing)<br />

LASt or USEr<br />

(flashing)<br />

# # . #<br />

(first digit flashing)<br />

# # . #<br />

(change flashing digit)<br />

(flashing)<br />

HOLD TO 22mA WHEN ERROR OFF or On<br />

(flashing)<br />

SEL CH1 or SEL CH2<br />

on main display of<br />

two channel analyzer<br />

Displayed if USEr<br />

was selected in<br />

previous screen<br />

Action required if<br />

USEr was selected in<br />

previous screen<br />

Action required if<br />

USEr was selected in<br />

previous screen<br />