Status Read Commands7 Error Code TableError Code Contents? Received data cannot be decoded;ORParameter designation error (wrong digit number, including invalid value, etc.).000 Normal reception (This is NOT an error.)101 Specified function is not available in the selected mode.102 Specified value is out of range (not reflected).103 Command mismatched to hardware (The command is for optional function, which isnot implemented.)201 Incremented or decremented value or values are beyond upper or lower limits.301 Not executable due to screen capture in process. Reissue the command after a while.302 Not executable due to auto set up in operation. Reissue the command after a while.303 Not executable due to memory card viewer in process. Reissue the command after awhile.402 Not executable due to PIN code in operation. Reissue the command after a while.<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 7-1020-000046-02 Rev 2 (07-2011)