Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Status Read Commands9.9 Lamp Status Read Commands9.9.1 CR_LAMPREPL CommandCommandDetail“CR_LAMPREPL” [CR]Get the information of Lamp Replacement timeResponse Acceptable “000_%1” [CR]%1 “2**” 2 - indicates 2 lamps are used in this model.*- indicates the status of each lamp in lamp numberorder.“Y” means the lamp operating time is over thethreshold for lamp replacement, and“N” means it has not reached to. e.g.“2YN” - This indicates it is 2-lamp system, andLamp #2 has not been reached to the replacementtime while #1 should be replaced.Unacceptable “?” [CR]9.9.2 CR_LAMPMODE CommandCommandDetail“CR_LAMPMODE” [CR]Get Lamp mode setting statusResponse Acceptable “000_%1” [CR]%1 “FULL” - Lamp mode is set to 4-lamp (FULL)“HALF” - Lamp mode is set to 2-lamp (HALF)Unacceptable “?” [CR]9.9.3 CR_AUTOLAMPCONTRL CommandCommandDetail“CR_AUTOLAMPCONTRL” [CR]Get selected Lamp control modeResponse Acceptable “000_%1” [CR]%1 “NORMAL” - NORMAL is selected.“ECO” - ECO is selected.“AUTO” - AUTO is selected.Unacceptable “Error Code” [CR]9-22 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)