Status Read Commands9.10.24 CR_TESTPAT CommandCommand “CR_TESTPAT” [CR]Detail Get setting status of Test patternResponse Acceptable “000_%1” [CR]%1 “COLOR” - Color bar is displayed“GRAD1” - 16step(white→black) is displayed“GRAD2” - 16step(white←black) is displayed“GRAD3” - 16step(white↓black) is displayed“GRAD4” - 16step(white↑black) is displayed“WHITE” - All white is displayed“BLACK” - All black is displayed“CROSS” - Cross is displayed“OFF” -Test pattern display is not displayedUnacceptable “Error Code” [CR]9.11 Other Status Read Commands9.11.1 CR_STATUS CommandCommand“CR_STATUS” [CR]Detail Get operating status of Projector Same as “CR0” in basic commandexcept error code follows it.Response Acceptable “000_%1” [CR]%1 “00” = Power ON“80” = Standby“40” = Countdown in process“20” = Cooling Down in process“10” = Power Failure“28” = Cooling Down in process due to abnormaltemperature“88” =Standby after Cooling Down due to abnormaltemperature“02” = Invalid RS-232C Command“24” = Power Save/Cooling Down in process“04” = Power Save“21” = Cooling Down in process after turned Off dueto lamp failure“81”= Standby after Cooling Down due to lampfailure“2C” = Cooling Down in process after Power Off dueto Shutter management“8C” = Standby after Cooling Down due to Shuttermanagement<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 9-31020-000046-02 Rev 2 (07-2011)