Status Read Commands8.8.2 CF_LAMPMODE CommandCommand“CF_LAMPMODE_%1” [CR]%1 “FULL” - Set lamp mode to 2-lamp (FULL)“HALF” - Set lamp mode to 1-lamp (HALF)Detail Select Lamp mode (valid only when in the normal Power ON status).The value set by this command is stored in EEPROM, and the settingremains effective after the power is turned to ALL OFF status. In Halfmode, one lamp with a lesser-used time lights automatically.Response Acceptable “000” [CR]Unacceptable“Error Code” [CR]8.8.3 CF_AUTOLAMPCONTRL CommandCommand“CF_AUTOLAMPCONTRL_%1” [CR]%1 “NORMAL” - Set lamp control mode to NORMAL“ECO” - Set lamp control mode to ECO“AUTO” - Set lamp control mode to AUTODetail Select Lamp control mode (valid only when in the normal Power ONstatus).The value set by this command is stored in EEPROM, and the settingremains effective after the power is turned to ALL OFF status.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8-24 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)