Status Read Commands9.10.21 CR_FILREPL CommandCommandDetail“CR_FILREPL” [CR]Get status of Filter cleaning/replacement timeResponse Acceptable “000_%1” [CR]%1 “1Y”-Filter Exchange time is over value of FilterMessage.“1N”-Filter Exchange time is not over value of FilterMessage.Unacceptable “Error Code” [CR]9.10.22 CR_FILTIMER CommandCommandDetail“CR_FILTIMER” [CR]Get time to display Filter cleaning/replacement warning on screenResponse Acceptable “000_%1” [CR]%1 “0400” - Display massage by 400h used.“0700” - Display massage by 700h used.“1000” - Display massage by 1000h used.“OFF” - Off(Warning display is not displayed)Unacceptable “Error Code” [CR]9.10.23 CR_FILREMAIN CommandCommandDetail“CR_FILREMAIN” [CR]Get remaining number of usable Filter scrollResponse Acceptable “000_%1” [CR]%1 “09” = Remaining number of usable Filter scroll : 9times :“00” = Remaining number of usable Filter scroll : 0timeUnacceptable “Error Code” [CR]9-30 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)