Status Read Commands9 Status Read Command9.1 FormatThe PC issues a command in the format below:“CR_Command” [CR]Command: StringWhen the projector receives the applicable command, it returns the required information as a datastring.“000_” %1 [CR]%1: required Information (a data string. Refer to [Basic Status Read Command Table])When the received data cannot be decoded, the projector returns “?” [CR]9.2 Transfer ExampleGetting total dots of the projector by Expand <strong>Serial</strong> CommandsPC → PJ: “CR_TDOTS” [CR]PC ← PJ: “000_1344” [CR]9.3 Operation conditionIt should always be operated.9.4 Image Status Read Commands9.4.1 CR_CONT CommandCommand “CR_CONT” [CR]Detail Get user controlled value of ContrastAcceptable “000_%1” [CR]Response %1 “000” – “063”Unacceptable “?” [CR]<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 9-1020-000046-02 Rev 2 (07-2011)