Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Status Read Commands9 Status Read Command9.1 FormatThe PC issues a command in the format below:“CR_Command” [CR]Command: StringWhen the projector receives the applicable command, it returns the required information as a datastring.“000_” %1 [CR]%1: required Information (a data string. Refer to [Basic Status Read Command Table])When the received data cannot be decoded, the projector returns “?” [CR]9.2 Transfer ExampleGetting total dots of the projector by Expand <strong>Serial</strong> CommandsPC → PJ: “CR_TDOTS” [CR]PC ← PJ: “000_1344” [CR]9.3 Operation conditionIt should always be operated.9.4 Image Status Read Commands9.4.1 CR_CONT CommandCommand “CR_CONT” [CR]Detail Get user controlled value of ContrastAcceptable “000_%1” [CR]Response %1 “000” – “063”Unacceptable “?” [CR]<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 9-1020-000046-02 Rev 2 (07-2011)