Status Read Commands9.9.8 CR_LAMPH CommandCommand“CR_LAMPH” [CR]Detail Get Lamp running time (in hours)*return actual lamp running timeResponse Acceptable “000_%1_%2_%3_%4” [CR]%1_%2 %3_%4Unacceptable9.10 Setting Status Read Commands9.10.1 CR_BACKGND CommandCommandDetail“CR_BACKGND” [CR]Lamp 1 data comes first, and then one space, afterthat lamp 2 data is followed.%1 = lamp No.1%2 = lamp No.2%3 = lamp No.3%4 = lamp No.4 ※In the case of 2-lamps model, % 1 and % 2 are onlyused (There are no % 3 and % 4.)Example: “0410_0410_0410_0410” [CR]▪▪▪▪ → Lamp No.1 = 410 HoursLamp No.2 = 410 HoursLamp No.3 = 410 HoursLamp No.4 = 410 HoursNote:• Each bit of data has 4 digits.• “9999” is returned for 10000 hours or more.“Error Code” [CR]Get setting status of Screen for no signalResponse Acceptable “000_%1” [CR]%1 “BLUE” - Blue Back is selected“USER” - User is selected“BLACK” - Black Back is selectedUnacceptable “Error Code” [CR]9-24 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)