12.07.2015 Views

Christie LW600 Serial Communications Protocol-Expanded

Christie LW600 Serial Communications Protocol-Expanded

Christie LW600 Serial Communications Protocol-Expanded

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Status Read Commands9.11.6 CR_TEMPWARN CommandCommand“CR_TEMPWARN” [CR]Detail Get the information about the temperature inside the projector (closeto the abnormal or in the abnormal status/in the safe temperaturelevel/abnormal status is not detected).It is possible to get the information about more than one sensor all atonce if it is applicable.Response Acceptable “000_%1” [CR]%1 “*_*” Sensor 1 data comes first, and then one space,after that sensor 2 data is followed. Each data is asbelow:“W”- in or close to the abnormal temp. (WarningTemp.)“S”- in the safe level of temperature (Safe Temp.).“N”- the given sensor does not detect abnormaltemp.Example: “S_W” [CR] indicates that the temperaturedetected at Sensor 1 is in the safe level while Sensor2 in the abnormal temperature.Unacceptable “?” [CR]<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 9-33020-000046-02 Rev 2 (07-2011)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!