Status Read Commands9.10.13 CR_SHUTRCPROT CommandCommandDetail“CR_SHUTRCPROT” [CR]Get status if Shutter can be controlled by R/CResponse Acceptable “000_%1” [CR]%1 “ON” - Shutter is not controllable by R/C“OFF” - Shutter is controllable by R/CUnacceptable “?” [CR]9.10.14 CR_SHUTKEYPROT CommandCommandDetail“CR_SHUTKEYPROT” [CR]Get status if Shutter can be controlled by key on the top panelResponse Acceptable “000_%1” [CR]%1 “ON” - Shutter is not controllable by key on the toppanel“OFF” - Shutter is controllable by key on the toppanelUnacceptable “?” [CR]9.10.15 CR_SHUTH CommandCommandDetail“CR_SHUTH” [CR]Get time setting to start the shutter managementResponse Acceptable “000_%1” [CR]%1 “005” -5 minutesUnacceptable“006” - 6 minutes :“179” - 179 minutes“180” - 180 minutes“?” [CR]9.10.16 CR_SECURITY CommandCommandDetail“CR_ SECURITY” [CR]Get ON/OFF setting status of Security on menu.Response Acceptable “000_%1” [CR]%1 “ON” - PJ is locked“OFF” - PJ is not locked.Unacceptable “Error Code” [CR]9-28 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)