Status Read Commands9.7 Input Read Command9.7.1 CR_INPUT CommandCommandDetail“CR_INPUT” [CR]Get selected INPUT No.Response Acceptable “000_%1” [CR]%1 “1” – “4”Unacceptable“?” [CR]9.7.2 CR_SOURCE CommandCommandDetail“CR_SOURCE” [CR]Get selected SourceResponse Acceptable “000_%1” [CR]%1 “DIGITAL” - DVI Input is selected“ANALOG - ANALOG RGB is selected“VIDEO” - Video Input is selected“S-VIDEO” - S-VIDEO Input is selected“YPBPR” - Y/Pb/Pr Input is selected“SDI1” - DF-SDI1 Input is selected“SDI2”- - DF-SDI2 Input is selected“HDCP” - HDCP Input is selected“SCART” - SCART Input is selected“NOCARD” - There is no board insertedUnacceptable “Error Code” [CR] - When command is invalid in thegiven condition (such as being selected input)“?” [CR] - When unknown command is received9-12 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)