Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
Christie LW600 Serial Communications Protocol-Expanded
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Status Read Commands9.7 Input Read Command9.7.1 CR_INPUT CommandCommandDetail“CR_INPUT” [CR]Get selected INPUT No.Response Acceptable “000_%1” [CR]%1 “1” – “4”Unacceptable“?” [CR]9.7.2 CR_SOURCE CommandCommandDetail“CR_SOURCE” [CR]Get selected SourceResponse Acceptable “000_%1” [CR]%1 “DIGITAL” - DVI Input is selected“ANALOG - ANALOG RGB is selected“VIDEO” - Video Input is selected“S-VIDEO” - S-VIDEO Input is selected“YPBPR” - Y/Pb/Pr Input is selected“SDI1” - DF-SDI1 Input is selected“SDI2”- - DF-SDI2 Input is selected“HDCP” - HDCP Input is selected“SCART” - SCART Input is selected“NOCARD” - There is no board insertedUnacceptable “Error Code” [CR] - When command is invalid in thegiven condition (such as being selected input)“?” [CR] - When unknown command is received9-12 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)