Status Read Commands9.10.9 CR_P-MANE CommandCommandDetail“CR_P-MANE” [CR]Get setting status of Power managementResponse Acceptable “000_%1” [CR]%1 “OFF” - Power Management is disabled“READY” - Power Management is set to Ready“SHUTDOWN” -Power Management is set to ShutDown modeUnacceptable “?” [CR]9.10.10 CR_P-MANETIME CommandCommandDetail“CR_P-MAETIME” [CR]Get setting time for starting Power Management functionResponse Acceptable “000_%1” [CR]%1 “001 – 030” - 1 to 30 minutesUnacceptable “?” [CR]9.10.11 CR_FANSPEED CommandCommandDetail“CR_FANSPEED” [CR]Get currently selected Fan Control SpeedResponse Acceptable “000_%1” [CR]%1 “MAX” - Max speed of Fan Control is selected“NOR” - Normal speed of Fan Control is selectedUnacceptable “?” [CR]9.10.12 CR_KEYDIS CommandCommandDetail“CR_KEYDIS” [CR]Get setting status of RC/KEY use limitation (valid or invalid)Response Acceptable “000_%1” [CR]%1 “NONE” - RC & KEY are valid“RC” - RC is invalid“KEY” - KEY is invalidUnacceptable “?” [CR]<strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information 9-27020-000046-02 Rev 2 (07-2011)