Status Read Commands9.5.9 CR_ORGMODE CommandCommandDetail“CR_ORGMODE” [CR]Get the original signal of current selected Mode that is set in PC Adj.When MODE1- 10 or EXT11-60 is not selected, get the current signal.Acceptable “000_%1” [CR]Response %1 When input signal is PC Analog;“VGA1” - Indicates signal Is VGA1“VGA2” - Indicates signal is VGA2:“XGA1” - Indicates signal is XGA1:“WXGA3” - Indicates signal is WXGA3“1080i60” - Indicates signal is 1080i60“1080i50” - Indicates signal is 1080i50“1035i” - Indicates signal is 10350i“720p60” - Indicates signal is 720p60“720p50” - Indicates signal is 720p50“575p” - Indicates signal is 575p“480p” - Indicates signal is 480p“575i” - Indicates signal is 575i“480i” - Indicates signal is 480i“1080psf/24” - Indicates signal is 1080psf/24“1080psf/25” - Indicates signal is 1080psf/25“1080psf/30” - Indicates signal is 1080psf/30Note: To differentiate between 60Hz and 50Hz in 1080iand 720p,60” or “50” is necessary to add to theparameter in this command.*When input signal is not PC Analog, error code“101” is returned.Unacceptable “?” [CR]9-10 <strong>LW600</strong>-LX900-LX1000 RS232 Codes-<strong>Expanded</strong> Technical Reference Information020-000046-02 Rev 2 (07-2011)