MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />

This operator enables the grouping together of two or<br />

three logic gates.<br />

A maximum of 8 inputs is foreseen.<br />

The result of the first two operators converges into a<br />

third operator, the result of which is the OUTPUT.<br />

Parameters<br />

Logic inputs 1, 2: enables the selection of the number<br />

of logic inputs (from 1 to 7).<br />

If one of the Logic Inputs equals "1", the corresponding logic is<br />

disabled and the input is directly connected to the end logic<br />

(refer to diagram opposite for example).<br />

Select Logic 1, 2, 3: enables the selection of one of the following types of operator:<br />

AND, NAND, OR, NOR, XOR, XNOR.<br />

Enable (OUT1, OUT2) If selected, activates an output with the result of the first two operators.<br />

Logical MULTIPLEXER forwards the signal of<br />

the inputs to the output according to the Sel<br />

selection. If the SEL1÷SEL4 have only one bit<br />

set, the selected In n is connected to the<br />

Output. If the SEL inputs are:<br />

- more than one = 1 (TRUE)<br />

- none = 1 (TRUE)<br />

the output is set to 0 (FALSE) independently<br />

from the In n values.<br />

Parameters<br />

Number of inputs: this is used to set between 2 and 4 inputs.<br />

English<br />

8540780 • 12/01/2016 • Rev.25 111