MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />

An external error or malfunction deriving from encoder/proximity or its wiring, does<br />

not necessarily involve a change of safety status of the normal output<br />

of<br />

the function block. Failures or malfunctions of encoder/proximity switch or its wiring<br />

are then recognized by the module, managed and specified via the diagnostic bit on<br />

every function block<br />

To ensure the safety features the diagnostic bit has to be used in the configuration<br />

program created by the user to cause a possible deactivation of the outputs if the<br />

axis is working. In absence of encoder/proximity external anomalies, bit will be<br />

equal to 0 (zero).<br />

In presence of encoder/proximity external anomalies, error_out bit will be equal<br />

to 1 (one):<br />

- Absence of encoder or proximity.<br />

- Absence of one or more wiring from encoder/proximity.<br />

- Absence of encoder power supply (only model with TTL external power supply).<br />

- Error of congruence frequencies between signals from encoder/proximity.<br />

- Phase error between signals from the encoder or duty cycle error of a single phase.<br />

Figure 54 – Example of speed control functional block with Error Out enabled<br />

English<br />

8540780 • 12/01/2016 • Rev.25 99