3) The counter generates a pulse duration equal to the system response time as soon as the<br />
set count is reached. If the CLEAR signal is activated, the internal count goes back to 0.<br />
Parameters<br />
Clear Enable: If selected this enables the request to clear in order to restart the counter<br />
setting output Q to 0 (FALSE). It also offers the possibility of enabling or not enabling<br />
(Automatic Enable) automatic operation with manual reset.<br />
If this is not selected operation is automatic. Once the set count is reached output Q is<br />
set to 1(TRUE) and stays in this condition for two internal cycles after which it is resetted.<br />
Ck down: Enables counting down.<br />
Two-way: If selected it enables counting on both the rising and falling edges.<br />
English<br />
118 8540780 • 12/01/2016 • Rev.25