22.10.2016 Views

REER-Mosaic Manual

MOSAIC - Installation and use manual

MOSAIC - Installation and use manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />

Parameters<br />

There are two types of reset: <strong>Manual</strong> and Monitored. When <strong>Manual</strong> is selected the system<br />

only verifies the signal's transition from 0 to 1. If Monitored is selected the double<br />

transition from 0 to 1 and then back to 0 is verified.<br />

t = 250 ms<br />

t1 > 250 ms<br />

t2 = 250 ms<br />

Important: for <strong>Manual</strong> reset always use the input immediately after those used by the<br />

function block. E.g.: if inputs 1 and 2 are used for the function block, use input 3 for<br />

Reset.<br />

The time that must pass between the<br />

( ).<br />

- 0 ms ÷ 1 s Step 100 ms<br />

- 1.5 s ÷ 10 s Step 0.5 s<br />

- 15 s ÷ 25 s Step 5 s<br />

input reaching and the real guard unlock<br />

Maximum delay accepted between output and input (must be the one shown<br />

on the lock data sheet with appropriate gap decided by the operator).<br />

- 10 ms ÷ 100 s Step 10 ms<br />

- 150 ms ÷ 1 s Step 50 ms<br />

- 1.5 s ÷ 3 s Step 0.5 s<br />

the cycle proceeds.<br />

Only with door opening and subsequent confirmation of input GATE,<br />

If selected, enables configuration without Gate but only with LOCK FEEDBACK<br />

(feedback coil lock).<br />

The guard is locked passively and released actively, i.e. the mechanical force of<br />

the spring keeps it locked. The guard thus continues to be locked even when the power supply is<br />

disconnected.<br />

English<br />

This can be selected to enable a signal (Error Out) to indicate a lock<br />

malfunction. When Error Out = 1 (TRUE) there is a fault in the lock.<br />