MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />
Print of the System composition with properties of each block. (Icon<br />
toolbar).<br />
on the standard<br />
This definition of PL and of the other related parameters as set forth in ISO 13849-1<br />
only refers to the functions implemented in the <strong>Mosaic</strong> system by the MSD<br />
configuration software, assuming configuration has been performed correctly.<br />
The actual PL of the entire application and the relative parameters must consider data<br />
for all the devices connected to the <strong>Mosaic</strong> system within the scope of the<br />
application.<br />
This must only be performed by the user/installer.<br />
English<br />
8540780 • 12/01/2016 • Rev.25 71