MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />
OUTPUT OBJECTS<br />
OSSD safety outputs which use semiconductor<br />
technology do not require maintenance, Output1<br />
and Output2 supply 24Vdc if the In is 1 (TRUE) and<br />
vice versa 0Vdc if the In is 0 (FALSE).<br />
Each pair of OSSD outputs has a relative<br />
RESTART_FBK input. This input must always<br />
be connected as indicated in the<br />
RESTART_FBK paragraph.<br />
Parameters<br />
<strong>Manual</strong> Reset: If selected this enables the request to reset each time the input signal falls.<br />
Otherwise, output enabling directly follows In input conditions.<br />
There are two types of reset:<br />
<strong>Manual</strong> and Monitored. In<br />
selecting the <strong>Manual</strong> option<br />
only signal transition from 0<br />
to 1 is verified. If the<br />
Monitored option is selected,<br />
the double transition from 0<br />
to 1 and back to 0 is verified.<br />
Enable Status: If selected,<br />
enables the connection of the<br />
current OSSD state to any<br />
point on the screen.<br />
K external time check: If selected, enables the setting of the time window within which the external<br />
feedback signal is to be monitored (according to output conditions).<br />
With high level (TRUE) OUTPUT, the FBK signal must be at low level (FALSE) and vice versa, within<br />
the set time.<br />
Otherwise, OUTPUT is set to low level (FALSE) and the error is indicated on the master M1 by the<br />
flashing CLEAR LED corresponding to the OSSD in error.<br />
Enable Error Out If selected, enables the ERROR OUT output. This output is set to high level (TRUE)<br />
when an external FBK error is detected.<br />
The<br />
t = 250ms<br />
signal is reset in case of one of the following events:<br />
1. Switching on and switching off of system.<br />
2. Activation of the RESET M1 operator.<br />
5s > t1 > 250ms<br />
t2 = 250ms<br />
English<br />
8540780 • 12/01/2016 • Rev.25 77