MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />

This operator applies a delay to a signal by setting the<br />

OUT output to 0 after the set time, set at a falling edge of<br />

the IN signal.<br />

If IN returns to 1 before the end of the set time, the OUT<br />

output still generates an LL0 impulse lasting<br />

approximately twice the response time and delayed by the<br />

set time.<br />

Parameters<br />

Time: Enables the insertion of the desired delay time by selecting the preferred unit of<br />

measurement. The delay can be set to between 10 ms and 1098.3 s.<br />

IN<br />

IN<br />

OUT<br />

t<br />

OUT<br />

t<br />

2xtrisp<br />

Unlike the DELAY operator, the DELAY LINE operator does not filter any<br />

interruptions in the IN input which are shorter than the set time.<br />

This operator is recommended when using delayed OSSD (the OSSD must be<br />

programmed with RESTART MANUAL).<br />