MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC<br />

The MONOSTABILE operator generates a level 1 (TRUE)<br />

output activated by the rising edge of the input and<br />

remains in this condition for the set time.<br />

Parameters<br />

Time: The delay can be set to between 10 ms and<br />

1098.3 s.<br />

Rising edge: If selected, the output is set to 1 (TRUE) on the input signal's rising edge<br />

where it remains for the set time, which can be extended for as long as the input stays at<br />

1 (TRUE).<br />

In<br />

Rising edge<br />

T T T<br />

Out<br />

If not selected the logic is inverted, the output is set to 0 (FALSE) on the input signal's<br />

falling edge, where it remains for the set time, which can be extended for as long as the<br />

input stays at 0 (FALSE).<br />

In<br />

Falling edge<br />

T T T<br />

Out<br />

Retriggerable: If selected the time is reset each time the input status changes.<br />