TIMER OPERATORS (max number = 32)<br />
TIMER operators allow you to generate a signal (TRUE or FALSE) for a user-definable<br />
period.<br />
The CLOCKING operator generates a clock signal<br />
output with the set period if the IN input is 1<br />
(TRUE). Clocking has up to 7 inputs to control<br />
output Duty Cycle.<br />
Parameters<br />
Time: The period can be set to between 10 ms and<br />
1098.3 s.<br />
Duty cycle selection: Up to 7 inputs can be<br />
selected for 7 different output signal duty cycles.<br />
Depending on the active input, the OUT clock signal has its corresponding duty cycle.<br />
EN input must always be high level (TRUE).<br />
Refer to the table below to check operator functioning.<br />
0 0 0 0 0 0 0 0 0 0<br />
0 0 0 0 0 0 0 0<br />
0 0 0 0 0 0 0<br />
0 0 0 0 0 0 0<br />
0 0 0 0 0 0<br />
0 0 0 0 0 0<br />
0 0 0 0 0 0<br />
0 0 0 0 0 0 0<br />
0 0 0 0 0 0 0<br />
0 0 0 0 0 0 0<br />
0 0 0 0 0 0<br />
The circuit upstream of the CLOCKING operator must guarantee the presence of a<br />
single input signal other than the EN enable (apart from the pair 10% 80%).<br />
The presence of the EN input together with > 1 high level (TRUE) inputs, generates<br />
an output signal with a duty cycle = 50%.<br />