Device Insertion Error When Using Elastomeric Pad<br />

Probable Cause Solution<br />

Device inserted<br />

improperly<br />

Messages<br />

Ensure that the device is properly justified in the socket or properly<br />

oriented in the MatchBook.<br />

WARNING:Do not press on the lid of the MatchBook to<br />

improve continuity. It compresses the pad, scratches and<br />

dents the base, and bends the pins on the device.<br />

Faulty device(s) Check the device for bent or damaged pins/leads. Repeat the operation<br />

with similar devices from the same manufacturer, and from other<br />

manufacturers. If the operation proves successful with similar devices,<br />

then the suspect part is probably defective.<br />

If the device has been in circuit or in a test or burn in socket, it may<br />

have bent pins. If so, it is not likely that the device will be able to be<br />

programmed with an elastomeric base. A PPI adapter with a discrete<br />

socket may be required to successfully program the device.<br />

Pad is dirty or worn Examine the pad for debris and wear. Clean or replace the pad as<br />

necessary. Refer to documentation for cleaning and replacement<br />

instructions.<br />

A raised or discolored pad is not necessarily bad. Examine it carefully<br />

prior to changing it.<br />

Base is dirty or worn Separate the compression ring from the base and examine the base<br />

with a magnifying glass or microscope. If any gold has worn off or<br />

there are scratches or dents in the gold traces, replace the base.<br />

Possible defect in<br />

programmer software<br />

associated with continuity<br />

check<br />

Continuity problem with<br />

device/programmer<br />

interface<br />

If this error occurs during an attempt to load the device (via Load<br />

Device from the Main Menu), disable the Continuity Check parameter<br />

(change from Y to N) in the Programming Parameters screen (via<br />

More/Configure system/Edit/ Programming options from the Main<br />

Menu). If the device is loaded successfully without insertion errors, try<br />

to program the device. If the device programs successfully, you've<br />

found a reasonable workaround.<br />

Note: Contact <strong>Data</strong> I/O Customer Support and report your<br />

findings.<br />

If following the steps described in the previous section causes the<br />

device to fail programming, a subtle continuity problem may exist.<br />

Workaround: Refer to your programmer's Device List and note the<br />

earliest version of the device that is supported by your programmer.<br />

Boot your programmer with any previous software version that<br />

supports the device and attempt the operation again. If the operation<br />

is successful with the earlier software, then you've found a temporary<br />

workaround.<br />

Note: Contact <strong>Data</strong> I/O Customer Support and report your<br />

findings.<br />