Performance Verification<br />

Figure A-4. Test Points on the Connector Block<br />

PIN 72<br />

(Plugged)<br />

PIN 78 (+10V)<br />

Checking the Master Clock<br />

1. Plug in the programmer and turn on the power switch.<br />

2. Check the 8 MHz clock signal by placing the ground probe of your<br />

frequency counter (or oscilloscope) on pin 1 (ground) of the 78-pin<br />

connector block. Place the test probe on pin 28 shown in Figure A-4.<br />

WARNING: Make sure the ground and test probes are on<br />

the correct pins.<br />

The clock signal should read as follows:<br />

Checking the Reference Voltages<br />

40<br />

78<br />

39<br />

1<br />

PIN 28 (8MHz)<br />

PIN 24 (+15V)<br />

PIN 1 (GROUND)<br />

Minimum Nominal Maximum<br />

7.999 MHz 8.000 MHz 8.001 MHz<br />

3. Check the +10 voltage reference by placing one probe of your digital<br />

multimeter on pin 78 (+10V) of the 78-pin connector. Place the other probe<br />

on pin 1 (ground). Both pin locations are shown Figure A-4.<br />

WARNING: Make sure the probes are on the correct connector pins.<br />

A-4 <strong>3980xpi</strong>/3980/3900/2900 User <strong>Manual</strong><br />