Illegal Bit Error<br />
Messages<br />
When this error occurs, the electronic ID of the device is displayed. You can also<br />
determine the electronic ID of your part by selecting the Compare Elec ID Device<br />
checks option (using the More/Device checks option from the Main Menu).<br />
The Compare elec ID parameter is located in the Load Device, Program Device,<br />
Verify Device, and Programming Parameters screens. To display the full parameter<br />
list under the Load Device, Program Device, and Verify Device screens, press the<br />
F4 function key.<br />
Probable Cause Solution<br />
Windowed device<br />
contains data<br />
Electrically erasable (EE)<br />
device contains data, and<br />
device's electronic erase<br />
feature is not enabled<br />
One Time Programmable<br />
(OTP) device contains<br />
data<br />
Perform a blank check on the device (using the More/Device checks<br />
options from the Main Menu) to determine whether is it truly blank. If<br />
blank check reports Non-blank device, place the device under a UV<br />
lamp and allow sufficient time for it to be fully erased. After erasure,<br />
reprogram the device.<br />
Make sure that the device's electronic erase feature (Erase EE Device<br />
parameter under the Program Device screen) is enabled (set to Y).<br />
Reprogram the device after the electronic erase feature has been<br />
enabled.<br />
Note: To display all parameters on the Program Device<br />
screen, press the F4 function key.<br />
Perform a blank check on the device to determine whether the device<br />
contains data. If so, your OTP device had previously been programmed<br />
and most likely cannot be over-programmed with different data or fuse<br />
pattern. Program another device.<br />
Faulty device(s) Program at least one more device labeled with the same date code. If it<br />
programs successfully, your original device was probably faulty. If<br />
other devices with the same date code also fail, attempt to program<br />
devices labeled with different date codes. If these devices program<br />
successfully, the devices from the original date code are probably<br />
faulty.<br />
Note: You may wish to contact the device manufacturer and<br />
report your findings.<br />
Improper algorithm<br />
applied by programmer<br />
due to recent change in<br />
manufacturer<br />
specifications<br />
Improper algorithm<br />
applied by programmer<br />
due to possible bug in<br />
programmer software<br />
If this error occurs only on devices with recent date codes, the devices<br />
may require a modified programming algorithm.<br />
Note: You may wish to contact the device manufacturer to<br />
determine whether the programming specifications for the<br />
device have changed.<br />
This error, if it occurs on devices with old to recent date codes, may<br />
indicate an algorithm-related problem in your programmer software.<br />
<strong>3980xpi</strong>/3980/3900/2900 User <strong>Manual</strong> 6-17